Evidence map›Paper›PMID 39381281›Full record

ArticleJournal of orthopaedic case reports2024

A Rare Case of Posterior Dislocation of Hinge Knee Prosthesis due to Wear of Anti-Luxation Device: A Case Report.

Vasav Somani, Ashraf Shaikh, Mohan M Desai, Nikhil Karwande, Kanav Somani

Abstract readCase Reports
In one paragraph

Article in Journal of orthopaedic case reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Vasav SomaniDepartment of Orthopaedics, Seth G.S. Medical College and K.E.M. Hospital, Mumbai, Maharashtra, India.
Ashraf ShaikhDepartment of Orthopaedics, Seth G.S. Medical College and K.E.M. Hospital, Mumbai, Maharashtra, India.
Mohan M DesaiDepartment of Orthopaedics, Seth G.S. Medical College and K.E.M. Hospital, Mumbai, Maharashtra, India.
Nikhil KarwandeDepartment of Orthopaedics, Seth G.S. Medical College and K.E.M. Hospital, Mumbai, Maharashtra, India.
Kanav SomaniDepartment of Orthopaedics, Seth G.S. Medical College and K.E.M. Hospital, Mumbai, Maharashtra, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Hinge knee joint prosthesis are utilized in a variety of surgical scenarios, including complex primary, revision, salvage surgeries, and radical resection of tumor's. Link's Endo-model Hinged Knee Prosthesis is a newer design that includes ramped tibial components for controlled pivot point motion during flexion and an anti-dislocation feature to prevent prosthesis dislocation.. The re-design of the hinge prosthesis has resulted in less force transfer along the implant bone junction. However, despite the improved design, complications can still arise. This report presents a rare complication of posterior dislocation due to polythene wear of the anti-dislocation device in a patient with a rotating hinge knee prosthesis. Case Report: After 4 years, a 42-year-old patient who had undergone multiple total knee replacements (TKRs) with a history of pain, swelling, and difficulty walking for the previous 2 months presented to us. Radiographs from the initial presentation revealed aseptic loosening, for which a revision TKR using a Link-Waldemier non-modular (rotational) joint endo-model with an anti-dislocation mechanism was performed. Three years later, the patient began experiencing episodes of instability, and a radiograph revealed posterior dislocation of the hinge knee prosthesis. As a result, a decision was made to perform revision surgery, during which the worn-out polyethylene was replaced with a new polyethylene insert, and stability was confirmed intraoperatively. Four weeks after surgery, the patient's knee range of motion was 0-120°, and all discomfort had completely subsided. At a year's follow-up, the patient's Knee Society score had improved from 40 before surgery to 90 after surgery. Conclusion: Interference in the normal framework of knee anatomy distorts its intrinsic stability. This interference can be in variable form such as bone deficiency, infection, multiple revision surgeries, and ligamentous laxity. Restoration of intrinsic stability in today's world has been made possible by a highly constraint, hinged knee prosthesis. An anti-dislocation mechanism on the rotating hinge prosthesis guards against dislocation brought on by distracted engagement. In our instance, the anti-dislocation mechanism had aseptically loosened, increasing flexion laxity and permitting severe distraction. The anti-dislocation mechanism will eventually relax, but its lifespan can be increased by proper gap balancing, which offers inherent stability and increases the anti-dislocation mechanism's stability.

Indexed as

Anti-dislocation mechanismdistraction stabilityendo-modelhinged total knee replacement

Identifiers

PMID39381281
PMCPMC11458250

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.