Evidence map›Paper›PMID 39380072›Full record

ArticleAntimicrobial resistance and infection control2024

The state of hand rub dispensers in healthcare settings - a multicenter assessment in 19 German healthcare facilities.

Christiane Herzer, Torsten Berg, Christine Hegemann, Tobias Gebhardt, Heide Niesalla, Christoph Senges

Abstract readMulticenter Study
In one paragraph

Article in Antimicrobial resistance and infection control, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Christiane HerzerGWA Hygiene GmbH, Stralsund, Germany.
Torsten BergGWA Hygiene GmbH, Stralsund, Germany.
Christine HegemannBODE Chemie GmbH, HARTMANN group, Hamburg, Germany.
Tobias GebhardtGWA Hygiene GmbH, Stralsund, Germany.
Heide NiesallaHARTMANN SCIENCE CENTER, BODE Chemie GmbH, HARTMANN group, Hamburg, Germany.
Christoph SengesHARTMANN SCIENCE CENTER, BODE Chemie GmbH, HARTMANN group, Hamburg, Germany. Christoph.senges@bode-chemie.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundHand hygiene is one of the most important hygiene measures to prevent healthcare-associated infections. Well-functioning hand rub dispensers are the foundation of hand hygiene but are often overlooked in research. As the point of origin for hand hygiene, dispensers not only promote compliance through ease of use, but also strongly influence the amount of hand rub used per disinfection. This work investigates how dispenser types and conditions affect dispensed volumes and usability.

methodsData from 5,014 wall-mounted or point-of-care dispensers was collected from 19 German healthcare facilities during installation of an electronic hand hygiene monitoring system, including dispenser type and dispensed hand rub volumes. Of these dispensers, 56.2% were metal dispensers, and the majority (89.5%) were wall-mounted. For one hospital, 946 wall-mounted dispensers were analyzed in detail regarding pump material, damages, functionality, cleanliness, and filling levels.

resultsDispensed volumes varied across and within dispenser types, ranging from 0.4 mL to 4.4 mL per full actuation, with the largest volumes generally dispensed by plastic dispensers with a preset of 1.0 to 3.0 mL per actuation. In general, most dispensers dispense more hand rub per full actuation than specified by the manufacturer. When different types of dispensers are used within a healthcare facility, vastly different volumes can be dispensed, making reliable and reproducible disinfection difficult for healthcare workers. In the detailed analysis of 946 dispensers, 27.1% had cosmetic defects, reduced performance, or were unusable, with empty disinfectant being the most common reason. Only 19.7% of working dispensers delivered their maximum volume on the first full actuation.

conclusionEven though several studies addressed the variability in dispensed volumes of hand hygiene dispensers, studies dealing with dispenser types and functionality are lacking, promoting the common but false assumption that different dispensers may be equivalent and interchangeable. Variability in dispensed volumes, coupled with frequent dispenser defects and maintenance issues, can be a major barrier to hand hygiene compliance. To support healthcare workers, more attention should be paid to 'dispenser compliance', selecting dispensers with similar volume ranges and proper maintenance.

Indexed as

Cross InfectionHand DisinfectionHealth FacilitiesGermanyHand HygieneHealth PersonnelHumansInfection ControlAlcohol-based hand rubHand antisepsisHand disinfectionHand hygiene dispenserPoint-of-care

Identifiers

PMID39380072
PMCPMC11462814

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.