ArticleJournal of orthopaedic surgery and research2024
Creation of a replicable anatomic model of terrible triad of the elbow.
Article in Journal of orthopaedic surgery and research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Ulnar Nerve Management in Complex Elbow Dislocations: A Retrospective Monocentric Study.Journal of personalized medicine · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTerrible triad of the elbow (TTE) is a complex dislocation associating radial head (RH) and coronoid process (CP) fractures. There is at present no reproducible anatomic model for TTE, and pathophysiology is unclear. The main aim of the present study was to create and validate an anatomic model of TTE. Secondary objectives were to assess breaking forces and relative forearm rotation with respect to the humerus before dislocation.
methodsAn experimental comparative study was conducted on 5 fresh human specimens aged 87.4 ± 8.6 years, testing 10 upper limbs. After dissection conserving the medial and lateral ligaments, interosseous membrane and joint capsule, elbows were reproducibly positioned in maximal pronation and 15° flexion, for axial compression on a rapid (100 mm/min) or slow (10 mm/min) protocol, applied by randomization between the two elbows of a given cadaver, measuring breaking forces and relative forearm rotation with respect to the humerus before dislocation.
resultsThe rapid protocol reproduced 4 posterolateral and 1 divergent anteroposterior TTE, and the slow protocol 5 posterolateral TTE. Mean breaking forces were 3,126 ± 1,066 N for the lateral collateral ligament (LCL), 3,026 ± 1,308 N for the RH and 2,613 ± 1,120 N for the CP. Comparing mean breaking forces for all injured structures in a given elbow on the rapid protocol found a p-value of 0.033. Comparison of difference in breaking forces in the three structures (LCL, RH and CP) between the slow and rapid protocols found a mean difference of -4%. Mean relative forearm rotation with respect to the humerus before dislocation was 1.6 ± 1.2° in external rotation.
conclusionsWe create and validate an anatomic model of TTE by exerting axial compression on an elbow in 15° flexion and maximal pronation at speeds of 100 and 10 mm/min.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.