Feasibility of Monitoring Heart and Respiratory Rates Using Nonwearable Devices and Consistency of the Measured Parameters: Pilot Feasibility Study.
Article in JMIR human factors, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: As Japan is the world's fastest-aging society with a declining population, it is challenging to secure human resources for care providers. Therefore, the Japanese government is promoting digital transformation and the use of nursing care equipment, including nonwearable devices that monitor heart and respiratory rates. However, the feasibility of monitoring heart and respiratory rates with nonwearable devices and the consistency of the rates measured have not been reported. Objective: In this study, we focused on a sheet-type nonwearable device (Safety Sheep Sensor) introduced in many nursing homes. We evaluated the feasibility of monitoring heart rate (HR) and respiratory rate (RR) continuously using nonwearable devices and the consistency of the HR and RR measured. Methods: A sheet-type nonwearable device that measured HR and RR every minute through body vibrations was placed under the mattress of each participant. The participants in study 1 were healthy individuals aged 20-60 years (n=21), while those in study 2 were older adults living in multidwelling houses and required nursing care (n=20). The HR was measured using standard methods by the nurse and using the wearable device (Silmee Bar-type Lite sensor), and RR was measured by the nurse. The primary outcome was the mean difference in HR and RR between nonwearable devices and standard methods. Results: The mean difference in HR was -0.32 (SD 3.12) in study 1 and 0.04 (SD: 3.98) in study 2; both the differences were within the predefined accepted discrepancies (<5 beats/min). The mean difference in RR was -0.98 (SD 3.01) in study 1 and -0.49 (SD 2.40) in study 2; both the differences were within the predefined accepted discrepancies (3 breaths/min). Conclusions: HR and RR measurements obtained using the nonwearable devices and the standard method were similar. Continuous monitoring of vital signs using nonwearable devices can aid in the early detection of abnormal conditions in older people.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.