Evidence map›Paper›PMID 39376945›Full record

ArticleDigital health

Breaking through diabetes management barriers: Assessing the accuracy of Freestyle Libre Pro flash continuous glucose monitoring in diabetes patients with myocardial infarction.

Long Shen, Li Xu, Chen Zhang, Wei-Wei Gong, Xiao-Ting Jing, Min-Jia Cao, Fang-Hong Shi, Jun Pu

Abstract read
In one paragraph

Article in Digital health. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Long ShenDepartment of Cardiology, Ren Ji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Li XuDepartment of Nursing, Ren Ji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Chen ZhangDepartment of Nursing, Ren Ji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Wei-Wei GongDepartment of Nursing, Ren Ji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Xiao-Ting JingDepartment of Nursing, Ren Ji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Min-Jia CaoDepartment of Pharmacy, Ren Ji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Fang-Hong ShiDepartment of Pharmacy, Ren Ji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.ORCID https://orcid.org/0000-0002-1409-7718
Jun PuDepartment of Cardiology, Ren Ji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: The objective of this study was to assess the accuracy of FreeStyle Libre Pro (FSL-Pro) flash continuous glucose monitoring (CGM) in patients with type 2 diabetes mellitus (T2DM) and acute myocardial infarction (AMI). Methods: A single-arm, single-center prospective study was conducted in the cardiac care unit from January 2021 to September 2023. Patients underwent finger-prick blood glucose (FPBG) testing before breakfast (6:00 am) and after meals (at 9:00, 13:00, 19:00 pm), along with CGM during their hospitalization. Statistical analyses included mean differences (MDs), mean absolute relative difference (MARDs) of blood glucose levels, and hypoglycemia occurrences. A Bland-Altman plot analysis and Pearson correlation were performed. Results: Ninety-seven T2DM and AMI patients underwent CGM for up to 72 h (1142 monitoring point). Mean daily BG, Fasting plasma glucose (FPG) and mean postprandial plasma glucose (PPG) were significantly lower by CGM than by FPBG with an estimated MD of -0.89 mmol/L in BG, -0.88 mmol/L in FPG, and -0.90 mmol/L in PPG, respectively. The maximum effect was mainly in the first day and then the difference was gradually declined (falling range, Day1, -1.24; Day 2, -0.70; Day 3, -0.68, mmol/L, respectively). The incidence rates of hypoglycemia and potential hypoglycemia was 1.57% and 8.5% higher, respectively, in CGM than in FBPG. A Bland-Altman Plot revealed some variability and bias between the two methods of measurement of glucose monitoring ( Conclusion: Compared with FPBG, FSL Pro-CGM showed lower mean glucose and higher hypoglycemia detection in T2DM and AMI patients, especially in the first 24 h.

Indexed as

continuous glucose monitoringfinger-prick blood glucoseFreeStyle Libre Promyocardial infarctiontype 2 diabetes mellitus

Identifiers

PMID39376945
PMCPMC11456750

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.