Evidence map›Paper›PMID 39376892›Full record

ArticleCureus2024

Peroneus Longus Tendon Graft in Extensor Mechanism Reconstruction After Total Knee Arthroplasty: A Viable Alternative.

Luis Henrique Longo, Marcos Paulo T Vanzin, Luis Antonio R Bauer, Carolline Popovicz Nunes, Lucas Rezende, Letícia H Miyamoto, Seiji G Nakahashi

Abstract readCase Reports
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Luis Henrique LongoOrthopaedics and Traumatology, Universidade Federal do Paraná, Hospital do Trabalhador, Curitiba, BRA.
Marcos Paulo T VanzinOrthopaedics and Traumatology, Universidade Federal do Paraná, Hospital do Trabalhador, Curitiba, BRA.
Luis Antonio R BauerOrthopaedics and Traumatology, Universidade Federal do Paraná, Hospital do Trabalhador, Curitiba, BRA.
Carolline Popovicz NunesOrthopaedics and Traumatology, Universidade Federal do Paraná, Hospital do Trabalhador, Curitiba, BRA.
Lucas RezendeOrthopaedics and Traumatology, Universidade Federal do Paraná, Hospital do Trabalhador, Curitiba, BRA.
Letícia H MiyamotoOrthopaedics and Traumatology, Universidade Federal do Paraná, Hospital do Trabalhador, Curitiba, BRA.
Seiji G NakahashiOrthopaedics and Traumatology, Universidade Federal do Paraná, Hospital do Trabalhador, Curitiba, BRA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The rupture of the extensor mechanism following total knee arthroplasty (TKA) is a rare and severe complication that poses a significant challenge in knee surgery. The rupture can occur in the patellar or quadriceps tendons or due to patellar fractures, leading to substantial functional deficits. Risk factors include multiple prior surgeries, systemic conditions, as well as iatrogenic injuries. Reconstruction techniques range from autografts, allografts, and synthetic materials to local flaps, but none have shown exceptional results. This case report describes extensor mechanism reconstruction using a peroneus longus tendon graft in a patient. A 74-year-old active female patient was referred from a rural area to a knee surgery referral hospital with a history of progressive osteoarthritis in the left knee and underwent TKA. At her first post-surgical follow-up, she was diagnosed with an extensor mechanism rupture and referred to our institution, being admitted six weeks postoperatively. On initial assessment, she presented difficulty in fully extending the knee and patellar elevation. Extensor mechanism reconstruction was indicated, using an autograft from the peroneus longus tendon due to limited access to tissue banks and synthetic materials. The graft was fixed using anchors and an interference screw, resulting in stable patellar tracking. Postoperatively, the patient followed a rehabilitation protocol with the use of a brace and gradual weight-bearing and mobility. One year after surgery, she demonstrated an unassisted gait without a limp, with restored extensor mechanism competence and a range of motion of 0-120 degrees. Several techniques have been described for patellar tendon reconstruction following TKA, but the results remain unsatisfactory. Most techniques involve the use of allografts, which, although moderately effective, can lead to residual deficits and the need for ambulatory aids. Synthetic materials have gained popularity but face challenges such as cost and tissue reactions. The use of autografts, like the peroneus longus tendon, has shown promise due to its robustness and adaptability. This report highlights a successful case of extensor mechanism reconstruction using the peroneus longus tendon. The peroneus longus tendon graft offers a viable alternative for extensor mechanism reconstruction after TKA: minimizes costs, reduces risks of tissue rejection and cross-infection, and facilitates early rehabilitation.

Indexed as

extensor mechanism knee injuriesextensor mechanism repairpatellar tendon ruptureperoneus longus tendon grafttotal knee arthroplasty

Identifiers

PMID39376892
PMCPMC11456417

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.