Evidence map›Paper›PMID 39375697›Full record

ArticleJournal of orthopaedic surgery and research2024

Biomechanical characteristics of ligament injuries in the knee joint during impact in the upright position: a finite element analysis.

Jia Li, Hanbing Liu, Mingyao Song, Fei Lin, Ziya Zhao, Zhenghui Wang, Liming Hou, Guoan Zhao, Wu Ren

Abstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Jia LiThe First Afiliated Hospital of Xinxiang Medical University, School of Medical Engineering, Xinxiang Medical University, Xinxiang, 453003, China.
Hanbing LiuThe First Afiliated Hospital of Xinxiang Medical University, School of Medical Engineering, Xinxiang Medical University, Xinxiang, 453003, China.
Mingyao SongThe First Afiliated Hospital of Xinxiang Medical University, School of Medical Engineering, Xinxiang Medical University, Xinxiang, 453003, China.
Fei LinThe First Afiliated Hospital of Xinxiang Medical University, School of Medical Engineering, Xinxiang Medical University, Xinxiang, 453003, China.
Ziya ZhaoThe First Afiliated Hospital of Xinxiang Medical University, School of Medical Engineering, Xinxiang Medical University, Xinxiang, 453003, China.
Zhenghui WangThe First Afiliated Hospital of Xinxiang Medical University, School of Medical Engineering, Xinxiang Medical University, Xinxiang, 453003, China.
Liming HouThe First Afiliated Hospital of Xinxiang Medical University, School of Medical Engineering, Xinxiang Medical University, Xinxiang, 453003, China. 780178657@qq.com.
Guoan ZhaoThe First Afiliated Hospital of Xinxiang Medical University, School of Medical Engineering, Xinxiang Medical University, Xinxiang, 453003, China. guoanzhao@xxmu.edu.cn.
Wu RenThe First Afiliated Hospital of Xinxiang Medical University, School of Medical Engineering, Xinxiang Medical University, Xinxiang, 453003, China. renwu88@126.com.

Funding

Henan Province Foundation for University Key Teacher 2021GGJS102Henan Provincial Medical Science and Technology Tackling Plan Joint Construction Project LHGJ20220609Key Scientific Research Project of Universities in Henan Province 22A416001Scientific Research Innovation Project of Xinxiang Medical University Students xskjzzd202356The open project program of the first hospital of Xinxiang Medical University XZZX2022005
6 · The paper itself

Abstract

backgroundOur study aims to examine stress-strain data of the four major knee ligaments-the anterior cruciate ligament (ACL), the posterior cruciate ligament (PCL), the medial collateral ligament (MCL), and the lateral collateral ligament (LCL)-under transient impacts in various knee joint regions and directions within the static standing position of the human body. Subsequently, we will analyze the varying biomechanical properties of knee ligaments under distinct loading conditions.

methodsA 3D simulation model of the human knee joint including bone, meniscus, articular cartilage, ligaments, and other tissues, was reconstructed from MRI images. A vertical load of 300 N was applied to the femur model's top surface to mimic the static standing position, and a 134 N load was applied to the impacted area of the knee joint. Nine scenarios were created to examine the effects of anterior, posterior, and lateral external forces on the upper, middle, and lower regions of the knee joint.

resultsThe PCL exhibited the highest stress levels among the four ligaments when anterior loads were applied to the upper, middle, and lower parts of the knee, with maximum stresses at the PCL-fibula junction measuring 59.895 MPa, 27.481 MPa, and 28.607 MPa, respectively. Highest stresses on the PCL were observed under posterior loads on the upper, middle, and lower knee areas, with peak stresses of 57.421 MPa, 38.147 MPa, and 26.904 MPa, focusing notably on the PCL-tibia junction. When a lateral load was placed on the upper knee joint, the ACL showed the highest stress 32.102 MPa. Likewise, in a lateral impact on the middle knee joint, the ACL also had the highest stress of 29.544 MPa, with peak force at the ACL-tibia junction each time. In a lateral impact on the lower knee area, the LCL had the highest stress of 22.279 MPa, with the highest force at the LCL-fibula junction. Furthermore, the maximum stress data table indicates that stresses in the ligaments are typically higher when the upper portion of the knee is affected compared to when the middle and lower parts are impacted.

conclusionsThis study recommends people avoid impacting the upper knee and use the middle and lower parts of the knee effectively against external forces to minimize ligament damage and safeguard the knee.

Indexed as

Finite Element AnalysisKnee JointBiomechanical PhenomenaHumansImaging, Three-DimensionalKnee InjuriesLigaments, ArticularMagnetic Resonance ImagingMalePosterior Cruciate LigamentStanding PositionStress, MechanicalWeight-BearingBiomechanical analysisFinite element modelHuman knee jointLigamentStress

Identifiers

PMID39375697
PMCPMC11457405

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.