Evidence map›Paper›PMID 39375430›Full record

ArticleScientific reports2024

Characterization of the oil water two phase flow in a novel microchannel contactor equipped with helical wire static mixer.

Sobhan Farahani, Salman Movahedirad, Mohammad Amin Sobati

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Developing Micro/Nanostructured Fluidic Mixing Technology for Biomedical Applications.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Sobhan FarahaniSchool of Chemical Engineering, Iran University of Science and Technology (IUST), P.O. Box 16765-163, Tehran, Iran.
Salman MovahediradSchool of Chemical Engineering, Iran University of Science and Technology (IUST), P.O. Box 16765-163, Tehran, Iran. movahedirad@iust.ac.ir.
Mohammad Amin SobatiSchool of Chemical Engineering, Iran University of Science and Technology (IUST), P.O. Box 16765-163, Tehran, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study investigates an oil/water two-phase system to assess the potential efficacy of a novel passive mixer in enhancing the liquid-liquid interfacial area within a micro-channel contactor. In this system, two fluids are introduced into a microchannel with a diameter of 800 μm and a length of 20 cm, which is equipped with a stainless-steel helical wire measuring 250 μm in diameter. Throughout the experiments, both fluids are supplied at equal flow rates, and the dominant forces, including attachment and detachment forces, are examined. The results reveal a critical Weber number of 3.8 × 10

Indexed as

Helical wireImage processingInterfacial areaLiquid-liquid two-phase flowMicrochannel

Identifiers

PMID39375430
PMCPMC11458776

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.