Evidence map›Paper›PMID 39371819›Full record

ArticleCureus2024

Diagnostic Accuracy and Incremental Value of Contrast-Enhanced Mammography Compared With Full Field Digital Mammography in a Tertiary Cancer Care Center.

Palak Popat, Venugopal Prudveesh Kumar Reddy Nandi, Aparna Katdare, Purvi Haria, Meenakshi Thakur, Suyash Kulkarni

Abstract read
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Palak PopatDepartment of Radiodiagnosis, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, IND.
Venugopal Prudveesh Kumar Reddy NandiDepartment of Radiodiagnosis, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, IND.
Aparna KatdareDepartment of Radiodiagnosis, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, IND.
Purvi HariaDepartment of Radiodiagnosis, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, IND.
Meenakshi ThakurDepartment of Radiodiagnosis, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, IND.
Suyash KulkarniDepartment of Radiodiagnosis, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, IND.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo assess the diagnostic accuracy and incremental value of contrast-enhanced mammography (CEM) compared with full-field digital mammography (FFDM). METHODOLOGY: A retrospective analysis was performed with 150 consecutive patients who underwent CEM at our institute between November 2020 and February 2021, fulfilling the inclusion criteria. The first round of analysis included a review of FFDM with an interpretation of findings as per the Breast Imaging Reporting and Data System (BIRADS) lexicon and the assignment of the BIRADS category to the detected abnormalities. After this documentation, a second round of analysis included a review of recombined subtracted images of CEM. The diagnostic accuracy of FFDM and CEM was calculated with histopathology as the gold standard.

resultsAmong the 150 cases assessed, 202 lesions were detected with histopathological correlation, of which 42 were benign and 160 were malignant. The sensitivity of FFDM was 90.6% compared to 98.12% for CEM. The specificity of FFDM was 66.7% compared to 76.19% for CEM. The negative predictive value (NPV) of FFDM was low, at 65.12%; CEM showed a better NPV, at 91.43%. The positive predictive value (PPV) was almost the same, at 94.01% for CEM and 91.19% for FFDM. The area under the curve (AUC) was superior for CEM compared to that of FFDM, with a value of 0.87. FFDM had a low sensitivity, especially in dense breast parenchyma, at 88.79% and a specificity of 70%, whereas CEM showed a higher sensitivity, specificity, and NPV, measuring 99.14%, 76.67%, and 95.83%, respectively.

conclusionSuperior sensitivity and high NPV for CEM make it a preferable modality compared with FFDM, especially in dense breast parenchyma, where CEM overcomes the limitations of FFDM. We conclude that CEM is superior to FFDM in evaluating the extent of disease, additional satellite lesion detection, and ruling out ambiguous findings.

Indexed as

cedmcemcesmcontrast-enhanced digital mammographycontrast-enhanced mammographycontrast-enhanced spectral mammographymammographysono-mammography

Identifiers

PMID39371819
PMCPMC11452313

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked