Evidence map›Paper›PMID 39371801›Full record

ArticleCureus2024

Assessing the Reliability of Postoperative Cross-Table Radiographs Compared to CT Scans for Measuring Acetabular Anteversion Angle Following Total Hip Arthroplasty.

Adhithya Kaushik, Vinay Kumar C, Anoop Hegde, Lawrence Mathias, Vikram Shetty

Abstract read
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Adhithya KaushikOrthopaedics, Meenakshi Medical College Hospital and Research Institute, Kanchipuram, IND.
Vinay Kumar COrthopaedics, K S Hegde Medical Academy, Mangalore, IND.
Anoop HegdeOrthopaedics, K S Hegde Medical Academy, Mangalore, IND.
Lawrence MathiasOrthopaedics, K S Hegde Medical Academy, Mangalore, IND.
Vikram ShettyOrthopaedics, K S Hegde Medical Academy, Mangalore, IND.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimThis study aimed to evaluate acetabular anteversion following total hip arthroplasty (THA) using cross-table lateral radiographs and CT scans and to determine the reliability of cross-table lateral radiographs compared to computed tomography (CT) scans for measuring acetabular anteversion. MATERIALS AND

methodsWe conducted a cross-sectional study of patients undergoing THA at Justice K.S. Hegde Charitable Hospital, Deralakatte, Mangalore, from January 2020 to June 2021. Radiographs are typically taken in both anteroposterior (AP) and lateral views after THA. However, for this study, a cross-table lateral view was used instead of the usual lateral radiograph to measure the angle of anteversion. The anteversion was calculated using the method described by Woo and Morrey. Additionally, CT scans were performed on all patients as part of the study protocol. The anteversion measured in these scans was compared to that in the cross-table radiographs to assess the latter's reliability for routine use. The risk of radiation exposure from CT scans was minimized by adhering to the ALARA (As Low as Reasonably Achievable) principle, with only axial sections of the acetabular cup being scanned.

resultsThe results show that the radiographic acetabular anteversion and CT scan measurements have a mean difference of 0.3036. There is a positive correlation between these measurements. The p-value is not statistically significant (p=0.698). Therefore, the measurements are correlated with each other with a linear relationship (r=0.919). For anteversion measurements using the X-ray method, the mean was 27.16 degrees with a standard deviation of ±9.49. The median was 27.26 degrees, ranging from 10.27 to 42.58 degrees. In comparison, the CT method yielded a mean anteversion of 27.40 degrees with a standard deviation of ±8.50 degrees. The median was 27.64 degrees, ranging from 12.35 to 43.11 degrees.

conclusionCross-table lateral radiographs are a reliable and comparable method to CT scans for measuring acetabular anteversion following total hip arthroplasty.

Indexed as

acetabulumcomputed tomographyhip arthroplastyhip prosthesisradiography

Identifiers

PMID39371801
PMCPMC11449688

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.