Combination of metal artifact reduction and sharpening filter application for horizontal root fracture diagnosis in teeth adjacent to a zirconia implant.

Débora Costa Ruiz, Larissa de Oliveira Reis, Rocharles Cavalcante Fontenele, Murilo Miranda-Viana, Amanda Farias-Gomes, Deborah Queiroz Freitas

Abstract read
In one paragraph

Article in Imaging science in dentistry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Débora Costa RuizDepartment of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil.ORCID https://orcid.org/0000-0002-2223-1286
Larissa de Oliveira ReisDepartment of Dentistry, Federal University of Juiz de Fora Campus Governador Valadares, Governador Valadares, MG, Brazil.ORCID https://orcid.org/0000-0002-4795-5248
Rocharles Cavalcante FonteneleOMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven, Leuven, Belgium.ORCID https://orcid.org/0000-0002-6426-9768
Murilo Miranda-VianaDepartment of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil.ORCID https://orcid.org/0000-0003-0370-3476
Amanda Farias-GomesDepartment of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil.ORCID https://orcid.org/0000-0002-4707-4838
Deborah Queiroz FreitasDepartment of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil.ORCID https://orcid.org/0000-0002-1425-5966

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: This study examined the influence of metal artifact reduction (MAR), the application of sharpening filters, and their combination on the diagnosis of horizontal root fracture (HRF) in teeth adjacent to a zirconia implant on cone-beam computed tomography (CBCT) examinations. Materials and Methods: Nineteen single-rooted teeth (9 with HRF and 10 without) were individually positioned in the right central incisor socket of a dry human maxilla. A zirconia implant was placed adjacent to each tooth. Imaging was performed using an OP300 Maxio CBCT (Instrumentarium, Tuusula, Finland) unit with the following settings: a current of 8 mA, both MAR modes (enabled and disabled), a 5×5 cm field of view, a voxel size of 0.085 mm, and a peak kilovoltage of 90 kVp. Four oral and maxillofacial radiologists independently evaluated the CBCT scans under both MAR conditions and across 3 levels of sharpening filter application (none, Sharpen 1×, and Sharpen 2×). Diagnostic metrics were calculated and compared using 2-way analysis of variance (α=5%). The weighted kappa test was used to assess intra- and inter-examiner reliability in the diagnosis of HRF. Results: MAR tool activation, sharpening filter use, and their combination did not significantly impact the area under the receiver operating characteristic curve, sensitivity, or specificity of HRF diagnosis ( Conclusion: The diagnosis of HRF in a tooth adjacent to a zirconia implant is not affected by the activation of MAR, the application of a sharpening filter, or the combination of these tools.

Indexed as

ArtifactsCone-Beam Computed TomographyDental ImplantsRadiographic Image EnhancementTooth Fractures

Identifiers

PMID39371300
PMCPMC11450410

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.