ArticleJournal of shoulder and elbow surgery2025
Isolated humeral distalization in reverse total shoulder arthroplasty: a biorobotic shoulder simulator study.
Article in Journal of shoulder and elbow surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- Relationship between implant positioning and post-operative scapulohumeral rhythm following reverse total shoulder arthroplasty.JSES international · 2026Article
- A CAD-to-Simulink framework for evaluating impingement-free motion in reverse total shoulder arthroplasty.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2026Article
- Quantifying dynamic muscle lengths and moment arms of musculoskeletal joints using FEBio studio: A demonstration in the glenohumeral joint.Journal of biomechanics · 2026Article
- Acromion to greater tuberosity distance: a simple radiographic key to unlocking optimal deltoid tension in reverse shoulder arthroplasty.Clinics in shoulder and elbow · 2026Article
- Accuracy of implant placement after preoperative planning using Blueprint software in inlay and onlay reverse total shoulder arthroplasty systems: a cadaver study.Journal of shoulder and elbow surgery · 2026Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
backgroundHumeral distalization is inherent to reverse total shoulder arthroplasty (rTSA) and is often produced with concomitant humeral lateralization via the level of the humeral head cut, implant positioning, implant neck shaft angle, and polymer insert thickness. Biomechanical data on the isolated effects of humeral distalization remain limited but could be important to consider when optimizing postoperative rTSA shoulder function. This study investigated the effects of isolated humeral distalization on shoulder biomechanics using a biorobotic shoulder simulator.
methodsEight fresh-frozen cadaveric shoulders were tested using custom polymer inserts that translated the bearing surface 0, +5, +10, and +15 mm along the humeral stem axis, producing isolated distalization without lateralization. Specimens underwent passive elevation in the scapular plane with a static scapula to assess glenohumeral range of motion. Scapular plane abduction motion trajectories were then performed, driven by previously collected scapulothoracic and glenohumeral kinematics from rTSA patients. The effect of isolated distalization on passive elevation was tested using mixed-effects linear regression and the effect on muscle force, joint reaction force, and muscle excursion during active scapular-plane abduction was tested using statistical parametric mapping random effects analysis.
resultsMaximum passive scapular plane elevation increased with humeral distalization (4° per 5 mm distalization). During active elevation, deltoid and rotator cuff muscle forces, and joint reaction forces, increased up to 37% per 5 mm of distalization. Simulated deltoid muscle excursion was altered with increasing distalization but amounted to no more than 0.8 mm change from baseline per 5 mm of distalization. Rotator cuff muscles were consistently lengthened throughout abduction, up to 1.6 mm per 5 mm of distalization. These trends were observed across various patient motions.
conclusionsIsolated humeral distalization caused dramatic increases in the muscle forces required to perform scapular-plane abduction. Joint reaction forces increased correspondingly. These results suggest that implant and surgical strategies to generate deltoid muscle tension without humeral distalization may promote better active range of motion and more durable long-term outcomes over approaches that rely on distalization.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials