Evidence map›Paper›PMID 39369015›Full record

ArticleScientific reports2024

Detecting cardiac states with wearable photoplethysmograms and implications for out-of-hospital cardiac arrest detection.

Mahsa Khalili, Saud Lingawi, Jacob Hutton, Christopher B Fordyce, Jim Christenson, Babak Shadgan, Brian Grunau, Calvin Kuo

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Mahsa KhaliliDepartment of Emergency Medicine, University of British Columbia, 2775 Laurel Street, Vancouver, BC, V5Z 1M9, Canada. mahsa.khalili@ubc.ca.ORCID http://orcid.org/0000-0002-0510-2554
Saud LingawiBritish Columbia Resuscitation Research Collaborative, Providence Research, 1190 Hornby Street, Vancouver, BC, V6Z 2K5, Canada.
Jacob HuttonDepartment of Emergency Medicine, University of British Columbia, 2775 Laurel Street, Vancouver, BC, V5Z 1M9, Canada.
Christopher B FordyceBritish Columbia Resuscitation Research Collaborative, Providence Research, 1190 Hornby Street, Vancouver, BC, V6Z 2K5, Canada.
Jim ChristensonDepartment of Emergency Medicine, University of British Columbia, 2775 Laurel Street, Vancouver, BC, V5Z 1M9, Canada.
Babak ShadganBritish Columbia Resuscitation Research Collaborative, Providence Research, 1190 Hornby Street, Vancouver, BC, V6Z 2K5, Canada.
Brian GrunauDepartment of Emergency Medicine, University of British Columbia, 2775 Laurel Street, Vancouver, BC, V5Z 1M9, Canada.
Calvin KuoBritish Columbia Resuscitation Research Collaborative, Providence Research, 1190 Hornby Street, Vancouver, BC, V6Z 2K5, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Out-of-hospital cardiac arrest (OHCA) is a global health problem affecting approximately 4.4 million individuals yearly. OHCA has a poor survival rate, specifically when unwitnessed (accounting for up to 75% of cases). Rapid recognition can significantly improve OHCA survival, and consumer wearables with continuous cardiopulmonary monitoring capabilities hold potential to "witness" cardiac arrest and activate emergency services. In this study, we used an arterial occlusion model to simulate cardiac arrest and investigated the ability of infrared photoplethysmogram (PPG) sensors, often utilized in consumer wearable devices, to differentiate normal cardiac pulsation, pulseless cardiac (i.e., resembling a cardiac arrest), and non-physiologic (i.e., off-body) states. Across the classification models trained and evaluated on three anatomical locations, higher classification performances were observed on the finger (macro average F1-score of 0.964 on the fingertip and 0.954 on the finger base) compared to the wrist (macro average F1-score of 0.837). The wrist-based classification model, which was trained and evaluated using all PPG measurements, including both high- and low-quality recordings, achieved a macro average precision and recall of 0.922 and 0.800, respectively. This wrist-based model, which represents the most common form factor in consumer wearables, could only capture about 43.8% of pulseless events. However, models trained and tested exclusively on high-quality recordings achieved higher classification outcomes (macro average F1-score of 0.975 on the fingertip, 0.973 on the finger base, and 0.934 on the wrist). The fingertip model had the highest performance to differentiate arterial occlusion pulselessness from normal cardiac pulsation and off-body measurements with macro average precision and recall of 0.978 and 0.972, respectively. This model was able to identify 93.7% of pulseless states (i.e., resembling a cardiac arrest event), with a 0.4% false positive rate. All classification models relied on a combination of time-, power spectral density (PSD)-, and frequency-domain features to differentiate normal cardiac pulsation, pulseless cardiac, and off-body PPG recordings. However, our best model represented an idealized detection condition, relying on ensuring high-quality PPG data for training and evaluation of machine learning algorithms. While 90.7% of our PPG recordings from the fingertip were considered of high quality, only 53.2% of the measurements from the wrist passed the quality criteria. Our findings have implications for adapting consumer wearables to provide OHCA detection, involving advancements in hardware and software to ensure high-quality measurements in real-world settings, as well as development of wearables with form factors that enable high-quality PPG data acquisition more consistently. Given these improvements, we demonstrate that OHCA detection can feasibly be made available to anyone using PPG-based consumer wearables.

Indexed as

Out-of-Hospital Cardiac ArrestPhotoplethysmographyWearable Electronic DevicesHumansMonitoring, PhysiologicCardiovascular MonitoringOut-of-hospital cardiac arrestPhotoplethysmographyWearable biosensors

Identifiers

PMID39369015
PMCPMC11455951

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.