Evidence map›Paper›PMID 39368121›Full record

Observational studyAnnals of Saudi medicine

Evaluation of optic nerve sheath diameter in patients undergoing laparoscopic surgery in the Trendelenburg position: a prospective observational study.

Burak Ömür, Bahadır Çiftçi, Pelin Karaaslan

Registry-linked trialAbstract readObservational Study
In one paragraph

Observational study in Annals of Saudi medicine. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07253922 (A Prospective Evaluation of Optic Nerve Sheath Diameter Changes Measured by Ultrasonography During Cardiopulmonary Bypass in Patients Undergoing Open Heart Surgery), which is not on this map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07253922 completednot on this map

A Prospective Evaluation of Optic Nerve Sheath Diameter Changes Measured by Ultrasonography During Cardiopulmonary Bypass in Patients Undergoing Open Heart Surgery

TypeobservationalSponsorMedipol UniversityRan2025 to 2025Enrolled40ConditionsOpen Heart Surgery, Cardiopulmonary Bypass, Intracranial Pressure, Optic Nerve Sheath DiameterArmsUltrasonography of the Optic Nerve Sheath
3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Trial
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Burak ÖmürFrom the Faculty of Medicine, Istanbul Medipol University, Istanbul, Turkey.ORCID 0000-0002-7241-200X
Bahadır ÇiftçiFrom the Faculty of Medicine, Istanbul Medipol University, Istanbul, Turkey.
Pelin KaraaslanFrom the Faculty of Medicine, Istanbul Medipol University, Istanbul, Turkey.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe Trendelenburg position and pneumoperitoneum may cause cerebral edema and increased intracranial pressure. Non-invasive measurement of the diameter of the optic nerve sheath by ultrasonography can provide early recognition of intracranial pressure.

objectiveEvaluate the optic nerve sheath diameter (ONSD) changes in patients who undergo laparoscopic surgery in the Trendelenburg position and make indirect conclusions about changes in intracranial pressure.

designProspective, observational.

settingLaparoscopic surgeries. PATIENTS AND

methodsPatients aged 18-75 years who underwent laparoscopic surgery in the Trendelenburg position under general anesthesia were included in our study. The ONSD was measured four times: Immediately after tracheal intubation, in the neutral position (baseline value) (T0), 10 minutes after pneumoperitoneum and Trendelenburg position (T1), 60 minutes after pneumoperitoneum and Trendelenburg position (T2), and 10 minutes after the pneumoperitoneum is terminated and placed in the neutral position (T3).

main outcome measuresCompare ONSD measured by ultrasonography at different times of surgery. SAMPLE SIZE: 40.

resultsArterial carbon dioxide pressure increased with laparoscopy and Trendelenburg position in parallel with ONSD measurements and decreased again after returning to the neutral position. It was still higher than the baseline value at the T3. There was also a significant difference[a] between the measurement made at the T2 and the measurement made at T1. This difference showed that the prolongation of the Trendelenburg time was associated with an increase in ONSD. At the end of the operation it was observed that the decreased statistically significantly (T3) 10 minutes after the pneumoperitoneum was terminated and the position was corrected. However, the ONSD was still higher at the end of the operation (T3) compared to the baseline value measured at the beginning of the operation (T0).

conclusionThe ONSD increased in relation to Trendelenburg position and pneumoperitoneum. With these results, we think the ultrasonographic measurement of ONSD, a non-invasive method, can be used for clinical follow-up when performing laparoscopic surgery in the Trendelenburg position in cases requiring intracranial pressure monitoring. LIMITATIONS: There may be variations in the measurement of ONSD, even in the measurements of the same practitioner, as in all imaging with an ultrasonography device.

Indexed as

Head-Down TiltIntracranial PressureLaparoscopyOptic NervePneumoperitoneum, ArtificialUltrasonographyAdolescentAdultAgedFemaleHumansIntracranial HypertensionMaleMiddle AgedPatient PositioningProspective Studies

Identifiers

PMID39368121
PMCPMC11454954

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.