ArticleScientific reports2024
Strong magnetic actuation system with enhanced field articulation through stacks of individually addressed coils.
Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
Abstract
Miniaturization of medical tools promises to revolutionize surgery by reducing tissue trauma and accelerating recovery. Magnetic untethered devices, with their ability to access hard-to-reach areas without physical connections, emerge as potential candidates for such miniaturization. Despite the benefits, these miniature devices face challenges regarding force and torque outputs, restricting their ability to perform tasks requiring mechanical interactions such as tissue penetration and manipulation. To overcome magnetic actuation system-based force and torque limitations, this study proposes Variable Outer Radius Individually Addressable Coil Stacks (VORIACS), a novel magnetic actuation system optimized for high force output generation to magnetic devices within its workspace. The VORIACS marks significant improvements and breakthroughs in magnetic actuation within decimeter-scale workspace. The VORIACS is comprised of 12 coils that are optimized for 2D magnetic field generation under maximized power consumption of up to 12 kW. We implement six two-channel motor controllers, powered by six separate power supplies. Each of the twelve coils in the system is operated on its own motor-controller channel. This arrangement allows the system to exceed the magnetic forces and torques possible for single-coil versions of the same geometry. This study elaborates on optimizing, manufacturing, integrating, and demonstrating this system. Comparative analysis reveals that while a suboptimal, single-coil version of this system generates 0.31 N force (710 mT/m magnetic gradient magnitude), the VORIACS produces 1.673 N force (3834 mT/m magnetic gradient magnitude) on the same magnetic object placed 5 cm away from the coils. Moreover, the strong penetration force generated by VORIACS enables needle penetration to a mock gel that has the rigidity of liver tissue. In addition, we demonstrate the advantage of stacked coils with variable radii for magnetic field manipulability while maintaining the optimized force delivery property of the system, which improves control and could facilitate multi-tool manipulation. By enabling a fivefold increase in magnetic pulling force compared to its single-coil counterpart, VORICAS raises the potential penetration capabilities of untethered magnetic robotics in surgical procedures.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.