Calculating optic nerve planning organ at risk volume margins for stereotactic radiosurgery using optic nerve motion determined using MRI.

Sagar Sabharwal, Geoff Heyes, George S J Tudor, Robert Flintham, Swarupsinh Chavda, Paul Sanghera

Abstract read
In one paragraph

Article in The British journal of radiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Sagar SabharwalDept Medical Physics, University Hospitals Birmingham NHS Foundation Trust, Birmingham, B152TH, United Kingdom.
Geoff HeyesDept Medical Physics, University Hospitals Birmingham NHS Foundation Trust, Birmingham, B152TH, United Kingdom.ORCID 0000-0001-8757-0193
George S J TudorDept Medical Physics, University Hospitals Birmingham NHS Foundation Trust, Birmingham, B152TH, United Kingdom.
Robert FlinthamDept Medical Physics, University Hospitals Birmingham NHS Foundation Trust, Birmingham, B152TH, United Kingdom.
Swarupsinh ChavdaDept Radiology, University Hospitals NHS Foundation Trust, Birmingham, B152TH, United Kingdom.
Paul SangheraDept Oncology, University Hospitals NHS Foundation Trust, Birmingham, B152TH, United Kingdom.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThe combination of sharp dose gradients in stereotactic radiosurgery (SRS) and minute optic nerve motion may significantly increase dose to the optic nerves when treating perioptic lesions. The aim of this study was to calculate optic nerve planning organ at risk volume (PRV) margins for CyberKnife SRS treatment planning.

methodsMRI scans were taken of 10 healthy volunteers looking left, right, up, down, and straight ahead to measure optic nerve motion. The measured optic nerve motion and the uncertainties in the technical accuracy of CyberKnife were used to calculate optic nerve PRV margins.

resultsTwo optic nerve PRV margins were calculated: a non-isotropic margin of mL/R,PRV=3 mm, mSup/Inf,PRV=2 mm, and mAnt/Post,PRV=1 mm which considers the full range of motion measured in a worst case scenario; and an isotropic margin of mPRV=1 mm which considers a scenario where patients are asked to look neutrally during imaging and treatment. Applying these PRVs to 8 historical sphenoid wing meningioma CyberKnife plans showed tolerance levels may be exceeded due to optic nerve motion.

conclusionsOptic nerve PRV margins may be needed in CyberKnife planning to reduce risk to the optic nerves. The use of a mPRV=1 mm PRV to account for organ motion, along with instructing patients to hold their gaze neutrally during imaging and treatment, may be a suitable organ sparing strategy. ADVANCES IN KNOWLEDGE: Measured optic nerve motion and the technical accuracy of the CyberKnife system have been used to calculate optic nerve PRV margins.

Indexed as

Magnetic Resonance ImagingOptic NerveOrgans at RiskRadiosurgeryAdultFemaleHealthy VolunteersHumansMaleMeningeal NeoplasmsMeningiomaRadiotherapy Planning, Computer-AssistedcyberknifeMRIoptic nerve motionPRV marginsradiotherapystereotactic radiosurgery

Identifiers

PMID39365704
PMCPMC11652728

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked