Observational studyJournal of medical Internet research2024
Evaluation of Machine Learning to Detect Influenza Using Wearable Sensor Data and Patient-Reported Symptoms: Cohort Study.
Observational study in Journal of medical Internet research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Integrating Artificial Intelligence with Wearable Sensors for Advanced Health Monitoring and Diagnosis.Biosensors · 2026Review
- One-Step RAA and CRISPR-Cas13a Method for Detecting Influenza B Virus.Microbial biotechnology · 2025Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundMachine learning offers quantitative pattern recognition analysis of wearable device data and has the potential to detect illness onset and monitor influenza-like illness (ILI) in patients who are infected.
objectiveThis study aims to evaluate the ability of machine-learning algorithms to distinguish between participants who are influenza positive and influenza negative in a cohort of symptomatic patients with ILI using wearable sensor (activity) data and self-reported symptom data during the latent and early symptomatic periods of ILI.
methodsThis prospective observational cohort study used the extreme gradient boosting (XGBoost) classifier to determine whether a participant was influenza positive or negative based on 3 models using symptom-only data, activity-only data, and combined symptom and activity data. Data were collected from the Home Testing of Respiratory Illness (HTRI) study and FluStudy2020, both conducted between December 2019 and October 2020. The model was developed using the FluStudy2020 data and tested on the HTRI data. Analyses included participants in these studies with an at-home influenza diagnostic test result. Fitbit (Google LLC) devices were used to measure participants' steps, heart rate, and sleep parameters. Participants detailed their ILI symptoms, health care-seeking behaviors, and quality of life. Model performance was assessed by area under the curve (AUC), balanced accuracy, recall (sensitivity), specificity, precision (positive predictive value), negative predictive value, and weighted harmonic mean of precision and recall (F
resultsAn influenza diagnostic test result was available for 953 and 925 participants in HTRI and FluStudy2020, respectively, of whom 848 (89%) and 840 (90.8%) had activity data. For the training and validation sets, the highest performing model was trained on the combined symptom and activity data (training AUC=0.77; validation AUC=0.74) versus symptom-only (training AUC=0.73; validation AUC=0.72) and activity-only (training AUC=0.68; validation AUC=0.65) data. For the FluStudy2020 test set, the performance of the model trained on combined symptom and activity data was closely aligned with that of the symptom-only model (combined symptom and activity test AUC=0.74; symptom-only test AUC=0.74). These results were validated using independent HTRI data (combined symptom and activity evaluation AUC=0.75; symptom-only evaluation AUC=0.74). The top features guiding influenza detection were cough; mean resting heart rate during main sleep; fever; total minutes in bed for the combined model; and fever, cough, and sore throat for the symptom-only model.
conclusionsMachine-learning algorithms had moderate accuracy in detecting influenza, suggesting that previous findings from research-grade sensors tested in highly controlled experimental settings may not easily translate to scalable commercial-grade sensors. In the future, more advanced wearable sensors may improve their performance in the early detection and discrimination of viral respiratory infections.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.