Evaluation of tear film function by Oculus Keratograph 5M and IDRA ocular surface analyser.

Jiajia Wang, Yan Shen, Xingtao Zhou, Zhiqiang Yu, Jiaxu Hong, Qihua Le

Abstract read
PubMed Publisher
In one paragraph

Article in International ophthalmology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jiajia WangDepartment of Ophthalmology, Eye & ENT Hospital Fudan University, Shanghai, China.
Yan ShenDepartment of Ophthalmology, Eye & ENT Hospital Fudan University, Shanghai, China.
Xingtao ZhouDepartment of Ophthalmology, Eye & ENT Hospital Fudan University, Shanghai, China.
Zhiqiang YuDepartment of Ophthalmology, Eye & ENT Hospital Fudan University, Shanghai, China.
Jiaxu HongKey Laboratory of Myopia and Related Eye Diseases, NHC, Shanghai, China. jiaxu.hong@fdeent.org.
Qihua LeDepartment of Ophthalmology, Eye & ENT Hospital Fudan University, Shanghai, China. qihuale_eent@163.com.

Funding

National Natural Science Foundation of China 81970766National Natural Science Foundation of China 81970767
6 · The paper itself

Abstract

purposeThe aim of this study was to evaluate the function of tear film with Oculus Keratograph 5M (Oculus K5M) and IDRA ocular surface analyser (IDRA), analyse their consistency and explore the potential of IDRA in the diagnosis of dry eye disease (DED).

methodsThis cross-sectional study enrolled 36 participants (DED group, 14 eyes; non-DED group, 22 eyes). The parameters of tear film function, including the first noninvasive breakup time (fNIBUT), average NIBUT (aNIBUT), tear meniscus height (TMH), lipid layer thickness (LLT), lipid layer colour (LLC), lipid layer uniformity (LLU), morphology of meibomian glands (MGs) and MG loss, were obtained with Oculus K5M and IDRA. The consistency of parameter measurements between the two devices was evaluated.

resultsAll the parameters except LLT, which can be measured only by IDRA, were not significantly different between the two instruments in DED eyes. However, IDRA reported lower values of fNIBUT, aNIBUT and TMH as well as higher MG loss scores in non-DED eyes than Oculus K5M did (p < 0.001, < 0.001, = 0.002, and = 0.002, respectively). Further regression analysis revealed that aNIBUT and LLT measured by IDRA were the optimal parameters for diagnosing DED (OR = 0.567 and 0.845, p = 0.057 and 0.043, respectively), and their combination had the strongest diagnostic potential (AUC = 0.841, sensitivity = 85.7%, and specificity = 77.3%).

conclusionAs a user-friendly noninvasive device, the tear film function parameters measured by IDRA were highly consistent with those measured by Oculus K5M in DED patients. The combination of aNIBUT and LLT measured by IDRA had the best diagnostic accuracy for DED.