Evidence map›Paper›PMID 39365437›Full record

ArticleWorld journal of urology2024

Ablation efficiency and laser safety of a novel superpulsed thulium fiber laser: a in vitro study.

Zhonghua Shen, Junjie Liang, Linguo Xie, Chunyu Liu

Abstract read
PubMed Publisher
In one paragraph

Article in World journal of urology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Zhonghua Shen *Department of Urology, Tianjin Institute of Urology, The Second Hospital of Tianjin Medical University, 23 Pingjiang Road, Hexi, Tianjin, 300000, People's Republic of China.
Junjie Liang *Department of Urology, Tianjin Institute of Urology, The Second Hospital of Tianjin Medical University, 23 Pingjiang Road, Hexi, Tianjin, 300000, People's Republic of China.
Linguo Xie *Department of Urology, Tianjin Institute of Urology, The Second Hospital of Tianjin Medical University, 23 Pingjiang Road, Hexi, Tianjin, 300000, People's Republic of China.
Chunyu LiuDepartment of Urology, Tianjin Institute of Urology, The Second Hospital of Tianjin Medical University, 23 Pingjiang Road, Hexi, Tianjin, 300000, People's Republic of China. prof_liucy@163.com.

Funding

The Science and Technology Project of Tianjin 21JCYBJC01300Tianjin Health Research Project TJWJ2022ZD004Tianjin Institute of Urology Project MYSRC202313
6 · The paper itself

Abstract

purposeTo assess the ablation efficiency of the Superpulsed Thulium Fiber Laser (SP-TFL) and investigate the thermal effects of SP-TFL.

methodsA SP-TFLwas employed to evaluate ablation efficiency. Fresh ex-vivo pig kidneys and ureters were utilized to evaluate the renal pelvis and ureter temperature changes, different irrigation rates(0, 15, 38mL/min) and a long pulse width were used.

resultsThe research indicated that as laser output power increased, ablation rates significantly increased. Ablation rates(mg/min) were higher and the energy per ablated mass(J/mg) was lower at lower frequencies(10-50 Hz). Under the same frequency and single pulse energy, super short and short pulse widths demonstrated higher ablation rates at higher frequencies (exceeding 100 Hz). The temperature of the renal pelvis and ureter decreased with increasing irrigation rates. In the renal pelvis, without irrigation, the temperature quickly reached the critical threshold of 43℃. The irrigation rate was 15 ml/min and power was no more than 18 W, the renal pelvis temperature did not reach 43℃. When the irrigation rate were 38 ml/min, the temperature did not risen to 43℃. In the ureter, without irrigation, the temperature also quickly reached 43℃. The temperature reached 43℃ when the power exceeded to12W with an irrigation rate of 15 ml/min. With an irrigation rate of 38 ml/min, the temperature reached 43℃ at a laser power of 30 W.

conclusionsThe SP-TFL demonstrated promising ablation effectiveness especially for lower frequencies and super short and short pulse widths model. Proper irrigation rates, single pulse energy, frequency and pulse width are crucial during lithotripsy.

Indexed as

Laser TherapyThuliumUreterAnimalsIn Vitro TechniquesKidneyLasers, Solid-StateSwineThuliumAblation efficiencyLithotripsyTemperatureThulium fiber laser

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.