Evidence map›Paper›PMID 39364098›Full record

ArticleClinics in orthopedic surgery2024

Comparison of Early Postoperative Stress Distribution around Short and Tapered Wedge Stems in Femurs with Different Femoral Marrow Cavity Geometries Using Finite Element Analysis.

Tsuguaki Hosoyama, Nobuhiro Kaku, Jonas A Pramudita, Yutaro Shibuta

Abstract readComparative Study
In one paragraph

Article in Clinics in orthopedic surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Tsuguaki HosoyamaDepartment of Orthopaedic Surgery, Faculty of Medicine, Oita University, Yufu, Japan.ORCID https://orcid.org/0000-0002-8505-6534
Nobuhiro KakuDepartment of Orthopaedic Surgery, Faculty of Medicine, Oita University, Yufu, Japan.ORCID https://orcid.org/0000-0002-4041-1870
Jonas A PramuditaDepartment of Mechanical Engineering, College of Engineering, Nihon University, Koriyama, Japan.ORCID https://orcid.org/0000-0002-5892-5925
Yutaro ShibutaDepartment of Orthopaedic Surgery, Faculty of Medicine, Oita University, Yufu, Japan.ORCID https://orcid.org/0000-0001-5555-0905

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Backgroud: In total hip arthroplasty (THA), the ideal stem length remains uncertain; different stem lengths are used in different cases or institutions. We aimed to compare the stress distributions of cementless tapered wedges and short stems in femurs with different femoral marrow geometries and determine the appropriate fit. Methods: Finite element models were created and analyzed using HyperMesh and LS-DYNA R11.1, respectively. The 3-dimensional shape data of the femurs were extracted from computed tomography images using the RETOMO software. Femurs were divided into 3 groups based on the Dorr classification. The computer-aided design data of cementless tapered wedge-type and short stems were used to select the appropriate size. In the finite element analysis, the loading condition of the femur was assumed to be walking. Volumes of interest (VOIs) were placed within the femur model at the internal and external contact points of the stem based on Gruen zones. The average stresses and strain energy density (SED) of the elements included in each VOI were obtained from the preoperative and postoperative models. Results: The von Mises stress and SED distributions of the cementless tapered wedge and short stems were similar in their respective Dorr classifications. In both stems, the von Mises stress and SED after THA were lower than before THA. The von Mises stress and SED of the cementless tapered wedge stem were higher than those of short stems. Cementless tapered wedge-type stems tended to have lower rates of change than short stems; however, Dorr C exhibited the opposite trend. In the Dorr classification comparison, the von Mises stress and SED were greater for both stems in the order of Dorr C > Dorr B > Dorr A, from Zone 2 to Zone 6. Conclusions: In Dorr A and B, the short stem exhibited a natural stress distribution closer to the preoperative femur than the tapered wedge stem; however, in Dorr C, the short stem may have a greater effect on stress distribution, suggesting that it may cause greater effects, such as fracture in the early postoperative period, than other Dorr types.

Indexed as

Arthroplasty, Replacement, HipFemurFinite Element AnalysisHip ProsthesisProsthesis DesignStress, MechanicalHumansTomography, X-Ray ComputedClassificationFemurFinite element analysisHip prosthesisStress

Identifiers

PMID39364098
PMCPMC11444945

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.