ArticleArtificial organs2025
Anatomical compatibility of a novel total artificial heart: An in-silico study.
Article in Artificial organs, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Anatomical compatibility of a novel total artificial heart: An in-silico study.Artificial organs · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
backgroundShuttlePump is a novel total artificial heart (TAH) recently introduced to potentially overcome the limitations associated with the current state-of-the-art mechanical circulatory support devices intended for adults. In this study, we adapted the outflow cannulation of the previously established ShuttlePump TAH and evaluated the anatomical compatibility using the virtual implantation technique.
methodsWe retrospectively assessed the anatomical compatibility of the ShuttlePump using virtual implantation techniques within 3D-reconstructed anatomies of adult heart failure patients. Additionally, we examined the impact of outflow cannula modification on the hemocompatibility of the ShuttlePump through computational fluid dynamic simulations.
resultsA successful virtual implantation in 9/11 patients was achieved. However, in 2 patients, pump interaction with the thoracic cage was observed and considered unsuccessful virtual implantation. A strong correlation (r <-0.78) observed between the measured anatomical parameters and the ShuttlePump volume exceeding pericardium highlights the importance of these measurements apart from body surface area. The numerical simulation revealed that the angled outflow cannulation resulted in a maximum pressure drop of 1.8 mmHg higher than that of the straight outflow cannulation. With comparable hemolysis index, the shear stress thresholds of angled outflow differ marginally (<5%) from the established pump model. Similar washout behavior between the pump models indicate that the curvature did not introduce stagnation zone.
conclusionThis study demonstrates the anatomic compatibility of the ShuttlePump in patients with biventricular failure, which was achieved by optimizing the outflow cannulation without compromising hemocompatibility. Nevertheless, clinical validation is critical to ensure the clinical applicability of these findings.