ArticleMedical & biological engineering & computing2025
Comparative biomechanical analysis of a conventional/novel hip prosthetic socket.
Article in Medical & biological engineering & computing, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
The aim of this study was to investigate and compare the biomechanical properties of the conventional and novel hip prosthetic socket by using the finite element and gait analysis. According to the CT scan model of the subject's residual limb, the bones, soft tissues, and the socket model were reconstructed in three dimensions by using inverse modeling. The distribution of normal and shear stresses at the residual limb-socket interface under the standing condition was investigated using the finite element method and verified by designing a pressure acquisition module system. The gait experiment compared and analyzed the conventional and novel sockets. The results show that the simulation results are consistent with the experimental data. The novel socket exhibited superior stress performance and gait outcomes compared to the conventional design. Our findings provide a research basis for evaluating the comfort of the hip prosthetic socket, optimizing and designing the structure of the socket of the hip.
Indexed as
Identifiers
39361102What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.