ArticleCureus2024

Superior Measurement Accuracy of Digital Thickness Gauge Versus Digital Vernier Caliper in Determining Venous Tissue Thickness.

Alexandru Petru Ion, Alexandra Asztalos, Claudiu Constantin Ciucanu, Eliza Russu, Adrian Vasile Muresan, Eliza-Mihaela Arbănași, Réka Bartus, Carmen Corina Radu, Traian V Chirilă, Emil-Marian Arbănași

Abstract read
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Analysis of digital vernier caliperFrontiers in bioengineering and biotechnology · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Alexandru Petru IonRegenerative Medicine Laboratory, Centre for Advanced Medical and Pharmaceutical Research (CCAMF), George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, Targu Mures, ROU.
Alexandra AsztalosDepartment of General Medicine, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, Targu Mures, ROU.
Claudiu Constantin CiucanuDepartment of Vascular Surgery, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, Targu Mures, ROU.
Eliza RussuDepartment of Vascular Surgery, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, Targu Mures, ROU.
Adrian Vasile MuresanDepartment of Vascular Surgery, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, Targu Mures, ROU.
Eliza-Mihaela ArbănașiRegenerative Medicine Laboratory, Centre for Advanced Medical and Pharmaceutical Research (CCAMF), George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, Targu Mures, ROU.
Réka BartusDepartment of Vascular Surgery, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, Targu Mures, ROU.
Carmen Corina RaduDepartment of Forensic Medicine, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, Targu Mures, ROU.
Traian V ChirilăRegenerative Medicine Laboratory, Centre for Advanced Medical and Pharmaceutical Research (CCAMF), George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, Targu Mures, ROU.
Emil-Marian ArbănașiRegenerative Medicine Laboratory, Centre for Advanced Medical and Pharmaceutical Research (CCAMF), George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, Targu Mures, ROU.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background In determining mechanical characteristics, the accuracy of the thickness of the specimens can influence the biomechanical behavior, especially in the case of human tissues, where there is an important variability. This study aims to compare the accuracy of two routine measuring instruments, i.e., the digital vernier caliper and the digital thickness gauge, when measuring the thickness of venous specimens multiple times. Methodology In this study, we used 12 tubular vena cava specimens obtained from common breed pigs aged 18-24 weeks at the time of sacrifice from a local slaughterhouse. The measurements were performed using a digital vernier caliper (Multicomp PRO MP012475) for the first four protocols and a digital thickness gauge (Mitutoyo 547-500S) for the fifth protocol. In the first protocol, three measurements were taken on the same side, and their average was recorded as the sample thickness. The second protocol involved taking measurements on two opposite sides, and the average of these measurements was recorded as the sample thickness. In the third protocol, the thickness of each side was measured at its midpoint, and the average of the four measurements was recorded as the sample thickness. In the last protocol using a digital vernier caliper, the thickness of the vernier specimens was calculated as the average of the measurements taken at each corner of the square sample. Finally, for the fifth protocol, three consecutive measurements were taken using the digital thickness gauge, and their average was recorded as the final thickness of the sample. Results In the first protocol, we observed lower values during the first measurement in comparison to the second (0.409 ± 0.063 vs. 0.536 ± 0.064, p < 0.0001) and the third (0.409 ± 0.063 vs. 0.528 ± 0.055, p = 0.0001). Moreover, with the second protocol, we observed lower values during the first two measurements in comparison to the third measurement (p = 0.0279 and p = 0.0054). Regarding protocols three and four, we recorded higher values for the second and third measurements than the first one, with higher values for the third measurement than the second one. In the fifth protocol, there were no significant statistical differences between the three consecutive measurements (p = 0.953, p = 0.742, and p = 0.897). Further, we examined the variations in sample thickness determined using each of the protocols proposed for the digital vernier caliper, as well as the values obtained with the digital thickness gauge protocol. As a result, during the first and second measurements, we observed lower thickness values for the venous wall samples using the first four protocols compared to the fifth protocol (for all p < 0.05). However, no differences were noted between the five protocols during the third measurement. Conclusions The digital thickness gauge Mitutoyo 547-500S provided superior accuracy with no difference between three successive measurements of venous wall thickness, regardless of the examiner's experience. Accurately determining the thickness of venous specimens is crucial for calculating the tissue's biomechanical properties.

Indexed as

biomechanicsdigital thickness gaugedigital vernier caliperspecimen thicknessvenous tissue