Evidence map›Paper›PMID 39356720›Full record

ArticlePLOS digital health2024

Automated image transcription for perinatal blood pressure monitoring using mobile health technology.

Nasim Katebi, Whitney Bremer, Tony Nguyen, Daniel Phan, Jamila Jeff, Kirkland Armstrong, Paula Phabian-Millbrook, Marissa Platner, Kimberly Carroll, Banafsheh Shoai and 4 more

Abstract read
In one paragraph

Article in PLOS digital health, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Nasim KatebiDepartment of Biomedical Informatics, Emory University, Atlanta, Georgia, United States of America.ORCID https://orcid.org/0000-0001-7750-0554
Whitney BremerDepartment of Biomedical Informatics, Emory University, Atlanta, Georgia, United States of America.
Tony NguyenDepartment of Biomedical Informatics, Emory University, Atlanta, Georgia, United States of America.
Daniel PhanDepartment of Biomedical Informatics, Emory University, Atlanta, Georgia, United States of America.
Jamila JeffDepartment of Gynecology and Obstetrics, Emory University, Atlanta, Georgia, United States of America.
Kirkland ArmstrongDepartment of Obstetrics and Gynecology, Morehouse School of Medicine, Atlanta, Georgia, United States of America.
Paula Phabian-MillbrookDepartment of Obstetrics and Gynecology, Morehouse School of Medicine, Atlanta, Georgia, United States of America.
Marissa PlatnerDepartment of Gynecology and Obstetrics, Emory University, Atlanta, Georgia, United States of America.
Kimberly CarrollDepartment of Obstetrics and Gynecology, Morehouse School of Medicine, Atlanta, Georgia, United States of America.
Banafsheh ShoaiDepartment of Obstetrics and Gynecology, Morehouse School of Medicine, Atlanta, Georgia, United States of America.
Peter RohloffCenter for Indigeous Health Research, Wuqu' Kawoq - Maya Health Alliance, Tecpán, Chimaltenango, Guatemala.
Sheree L BouletDepartment of Gynecology and Obstetrics, Emory University, Atlanta, Georgia, United States of America.
Cheryl G FranklinDepartment of Obstetrics and Gynecology, Morehouse School of Medicine, Atlanta, Georgia, United States of America.
Gari D CliffordDepartment of Biomedical Informatics, Emory University, Atlanta, Georgia, United States of America.

Funding

Implementing a Maternal health and PRegnancy Outcomes Vision for Everyone (IMPROVE)UL1TR002378 · NCATS · EMORY UNIVERSITY · PI Andres J Garcia, Elizabeth O. Ofili · 2017 to 2026
$92.1M
Institutional Career Development CoreKL2TR002542 · NCATS · HARVARD MEDICAL SCHOOL · PI BREDELLA, MIRIAM ANTOINETTE, RUTKOVE, SEWARD B. · 2018 to 2022
$8.7M
AI-driven low-cost ultrasound for automated quantification of hypertension, preeclampsia, and IUGRR01HD110480 · NICHD · EMORY UNIVERSITY · PI Gari David Clifford · 2022 to 2026
$3.1M
Atlanta Clinical and Translational Science Institute (ACTSI) RenewalKL2TR000455 · NCATS · EMORY UNIVERSITY · PI STEPHENS, DAVID S · 2012 to 2016
$2.9M
Pediatric and Reproductive Environmental Health Scholars Southeastern Environmental Exposures and Disparities (PREHS SEED) ProgramK12ES033593 · NIEHS · EMORY UNIVERSITY · PI Linda A. McCauley · 2022 to 2026
$2.4M
Mobile Health Intervention to Improve Perinatal Continuum of Care in GuatemalaR21HD084114 · NICHD · EMORY UNIVERSITY · PI CLIFFORD, GARI DAVID · 2015 to 2016
$374k
NCATS NIH HHS KL2 TR000455NCATS NIH HHS KL2 TR002542NCATS NIH HHS UL1 TR002378NICHD NIH HHS R01 HD110480NICHD NIH HHS R21 HD084114NIEHS NIH HHS K12 ES033593
6 · The paper itself

Abstract

This paper introduces a novel approach to address the challenges associated with transferring blood pressure (BP) data obtained from oscillometric devices used in self-measured BP monitoring systems to integrate this data into medical health records or a proxy database accessible by clinicians, particularly in low literacy populations. To this end, we developed an automated image transcription technique to effectively transcribe readings from BP devices, ultimately enhancing the accessibility and usability of BP data for monitoring and managing BP during pregnancy and the postpartum period, particularly in low-resource settings and low-literate populations. In the designed study, the photos of the BP devices were captured as part of perinatal mobile health (mHealth) monitoring programs, conducted in four studies across two countries. The Guatemala Set 1 and Guatemala Set 2 datasets include the data captured by a cohort of 49 lay midwives from 1697 and 584 pregnant women carrying singletons in the second and third trimesters in rural Guatemala during routine screening. Additionally, we designed an mHealth system in Georgia for postpartum women to monitor and report their BP at home with 23 and 49 African American participants contributing to the Georgia I3 and Georgia IMPROVE projects, respectively. We developed a deep learning-based model which operates in two steps: LCD localization using the You Only Look Once (YOLO) object detection model and digit recognition using a convolutional neural network-based model capable of recognizing multiple digits. We applied color correction and thresholding techniques to minimize the impact of reflection and artifacts. Three experiments were conducted based on the devices used for training the digit recognition model. Overall, our results demonstrate that the device-specific model with transfer learning and the device independent model outperformed the device-specific model without transfer learning. The mean absolute error (MAE) of image transcription on held-out test datasets using the device-independent digit recognition were 1.2 and 0.8 mmHg for systolic and diastolic BP in the Georgia IMPROVE and 0.9 and 0.5 mmHg in Guatemala Set 2 datasets. The MAE, far below the FDA recommendation of 5 mmHg, makes the proposed automatic image transcription model suitable for general use when used with appropriate low-error BP devices.

Identifiers

PMID39356720
PMCPMC11446426

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.