Evidence map›Paper›PMID 39355033›Full record

ArticleFrontiers in nuclear medicine2023

Insights into handling and delivery of Y-90 radioembolization therapies.

Dustin R Osborne, Gregory Minwell, Bradley Pollard, Chris Walker, Shelley N Acuff, Kristen Smith, Cain Green, Rachel Taylor, Christopher D Stephens

Abstract read
In one paragraph

Article in Frontiers in nuclear medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Dustin R OsborneDepartment of Radiology, University of Tennessee Graduate School of Medicine, Knoxville, TN, United States.
Gregory MinwellDepartment of Radiology, University of Tennessee Graduate School of Medicine, Knoxville, TN, United States.
Bradley PollardDepartment of Radiology, University of Tennessee Graduate School of Medicine, Knoxville, TN, United States.
Chris WalkerDepartment of Radiology, University of Tennessee Graduate School of Medicine, Knoxville, TN, United States.
Shelley N AcuffDepartment of Radiology, University of Tennessee Graduate School of Medicine, Knoxville, TN, United States.
Kristen SmithDepartment of Radiology, University of Tennessee Graduate School of Medicine, Knoxville, TN, United States.
Cain GreenDepartment of Radiology, University of Tennessee Graduate School of Medicine, Knoxville, TN, United States.
Rachel TaylorDepartment of Radiology, University of Tennessee Graduate School of Medicine, Knoxville, TN, United States.
Christopher D StephensDepartment of Radiology, University of Tennessee Graduate School of Medicine, Knoxville, TN, United States.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: The use of Y-90 radioembolization techniques has become a standard tool for the treatment of liver cancer and metastatic diseases that result in liver lesions. As there are only two approved forms of radioembolization therapy, the procedures for use are also fairly standardized even though exact international and interdepartmental procedures can vary. What has been less published over the years are the nuanced differences in delivery techniques and handling of the two available Y90 radioembolization therapies. This paper seeks to examine various aspects of delivery techniques, product handling, and radiation exposure that differ between the available and approved products. Understanding these differences can assist with providing more efficient treatment, confirmation of accurate therapy, more informed handling of the products, and improved training of physicians and other hospital staff. Methods: Two commercially available and approved radioembolization devices were compared to assess nuanced, but key differences between the available products regarding therapy delivery, handling of the products, and radiation exposure to patients and staff. This work is broken into two sections: (1) Therapy Delivery, (2) Radiation Safety. Therapy delivery characteristics were assessed by using an external radiation detector system with detectors placed inside of each delivery system facing the dose vial and on the output catheter lines to the patient. Additional detectors were placed near the liver of the patient and on top of the foot to measure extremities. Data were acquired continuously throughout therapy delivery to collect time activity curves (TACs) for the characterization of each therapy. These data were analyzed to assess if (a) real-time monitoring of radiation could be used to provide an accurate assessment of residual dose before the patient leaves the procedure room, and (b) can dose delivery characteristics be observed that enable improved training and quality control. Calculation of residual dose using the external detector TACs was performed by analyzing initial and final activity peaks to determine measured count rate differences. Radiation safety aspects were assessed by monitoring radiation exposure to staff handling each of the available therapy products. Nuclear medicine technologists and interventional radiology physician body and hand doses were measured for each delivered therapy using standard body and ring dosimeters. The TACs noted above collected for the liver and extremities were used to assess if any off-target or leached Y90 activity could be detected for each therapy. Blood was collected at times before, during, and after treatment and then counted on a gamma counter to assess differences in free Y90 circulating in the blood. Each patient in this study also received a post-treatment whole-body PET/CT at 2-4 h post-infusion to assess for any aggregate free Y90 deposition that may have resulted from circulating free Y90 in the subject following therapy. Results: Calculations of residual dose in the vial following therapy using the real-time detection methods resulted in values that were not statistically different from the values calculated by nuclear medicine following the procedure ( Conclusion: Although glass and resin radioembolization therapies are similar, they both have unique characteristics related to their administration and handling by staff. Understanding the nuances can assist in providing more efficient delivery, better staff education, and reducing radiation exposure to everyone involved with these therapies. The use of near real-time monitoring is feasible and can be used to obtain critical information about the delivery success of a therapy and can inform physicians on their techniques to optimize their practice as well as provide more consistent training to residents.

Indexed as

dosimetryPET/CTradiation safetyradioembolizationresidual dosetherapyY90Yttrium-90

Identifiers

PMID39355033
PMCPMC11440876

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.