Evidence map›Paper›PMID 39354823›Full record

ArticleRadiation oncology journal2024

Optimizing target and diaphragmatic configuration, and dosimetric benefits using continuous positive airway pressure in stereotactic ablative radiotherapy for lung tumors.

Jung Bin Park, Joo Ho Lee, Ji Hyun Chang, Jaeman Son, Seho Kwon, Su Yun Choi, Hyun-Woo Shin, Tosol Yu, Hak Jae Kim

Abstract read
In one paragraph

Article in Radiation oncology journal, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Jung Bin ParkDepartment of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea.
Joo Ho LeeDepartment of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea.
Ji Hyun ChangDepartment of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea.
Jaeman SonDepartment of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea.
Seho KwonSeoul National University College of Medicine, Seoul, Republic of Korea.
Su Yun ChoiSeoul National University College of Medicine, Seoul, Republic of Korea.
Hyun-Woo ShinObstructive Upper Airway Research Laboratory, Department of Pharmacology, Seoul National University College of Medicine, Seoul, Republic of Korea.
Tosol YuDepartment of Radiation Oncology, Seoul National University College of Medicine, Seoul, Republic of Korea.
Hak Jae KimDepartment of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea.

Funding

Dongnam Institute of Radiological & Medical Sciences 50602-2020Ministry of Science and ICTSeoul National University Hospital Research Fund 03-2022-2150
6 · The paper itself

Abstract

purposeThis study aimed to evaluate the impact of facilitating target delineation of continuous positive airway pressure (CPAP) in patients undergoing stereotactic ablative radiation therapy (SABR) for lung tumors by lung expansion and respiratory motion management. MATERIALS AND

methodsWe performed a prospective single-institutional trial of patients who were diagnosed with either primary lung cancer or lung metastases and received SABR with a dose of 40 to 60 Gy in 4 fractions. Four-dimensional computed tomography simulations were conducted for each patient: once without CPAP and again with CPAP.

resultsThirty-two patients with 39 tumors were analyzed, after the withdrawal of five patients due to discomfort. For 26 tumors separated from the diaphragm, CPAP significantly increased the superoinferior distance between the tumor and the diaphragm (5.96 cm vs. 8.06 cm; p < 0.001). For 13 tumors located adjacent to the diaphragm, CPAP decreased the overlap of planning target volume (PTV) with the diaphragm significantly (6.32 cm3 vs. 4.09 cm3; p = 0.002). PTV showed a significant reduction with CPAP (25.06 cm3 vs. 22.52 cm3, p = 0.017). In dosimetric analyses, CPAP expanded lung volume by 58.4% with a significant reduction in mean dose and V5 to V40. No more than grade 2 adverse events were reported.

conclusionThis trial demonstrated significant improvement of CPAP in target delineation uncertainties for lung SABR, with dosimetric benefits, a favorable safety profile and tolerability. Further investigation is warranted to explore the role of CPAP as a novel strategy for respiratory motion management.

Indexed as

Continuous positive airway pressureImage segmentationLung neoplasmsRadiotherapyRespiratory-gated imaging techniquesStereotactic body radiotherapy

Identifiers

PMID39354823
PMCPMC11467486

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.