Evidence map›Paper›PMID 39354526›Full record

ArticleBMC medical informatics and decision making2024

Enhancing visual seismocardiography in noisy environments with adaptive bidirectional filtering for Cardiac Health Monitoring.

Geetha N, C Rohith Bhat, Mahesh Tr, Temesgen Engida Yimer

Abstract read
In one paragraph

Article in BMC medical informatics and decision making, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Geetha NDepartment of Information Technology, Coimbatore Institute of Technology, Coimbatore, India.
C Rohith BhatDepartment of Computer Science and Engineering, Saveetha School of Engineering, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India.
Mahesh TrDepartment of Computer Science and Engineering, JAIN (Deemed-to-be University), Bengaluru, 562112, India.
Temesgen Engida YimerDepartment of Mathematics, Dilla University, Dilla, Ethiopia. Temesgen.engida@du.edu.et.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWearable sensors have revolutionized cardiac health monitoring, with Seismocardiography (SCG) at the forefront due to its non-invasive nature. However, the substantial motion artefacts have hindered the translation of SCG-based medical applications, primarily induced by walking. In contrast, our innovative technique, Adaptive Bidirectional Filtering (ABF), surpasses these challenges by refining SCG signals more effectively than any motion-induced noise. ABF leverages a noise-cancellation algorithm, operating on the benefits of the Redundant Multi-Scale Wavelet Decomposition (RMWD) and the bidirectional filtering framework, to achieve optimal signal quality. METHODOLOGY: The ABF technique is a two-stage process that diminishes the artefacts emanating from motion. The first step by RMWD is the identification of the heart-associated signals and the isolating samples with those related frequencies. Subsequently, the adaptive bidirectional filter operates in two dimensions: it uses Time-Frequency masking that eliminates temporal noise while engaging in non-negative matrix Decomposition to ensure spatial correlation and dorsoventral vibration reduction jointly. The main component that is altered from the other filters is the recursive structure that changes to the motion-adapted filter, which uses vertical axis accelerometer data to differentiate better between accurate SCG signals and motion artefacts. OUTCOME: Our empirical tests demonstrate exceptional signal improvement with the application of our ABF approach. The accuracy in heart rate estimation reached an impressive r-squared value of 0.95 at - 20 dB SNR, significantly outperforming the baseline value, which ranged from 0.1 to 0.85. The effectiveness of the motion-artifact-reduction methodology is also notable at an SNR of - 22 dB. Consequently, ECG inputs are not required. This method can be seamlessly integrated into noisy environments, enhancing ECG filtering, automatic beat detection, and rhythm interpretation processes, even in highly variable conditions. The ABF method effectively filters out up to 97% of motion-related noise components within the SCG signal from implantable devices. This advancement is poised to become an integral part of routine patient monitoring.

Indexed as

Signal Processing, Computer-AssistedAlgorithmsArtifactsHeart RateHumansMonitoring, PhysiologicWearable Electronic DevicesArtefactsDecompositionFilteringHealth monitoringHeartbeatMotionNoiseReductionSignalVisual seismocardiography

Identifiers

PMID39354526
PMCPMC11445874

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.