Evidence map›Paper›PMID 39354443›Full record

ArticleBMC oral health2024

Accuracy of implant abutment level digital impressions using stereophotogrammetry in edentulous jaws: an in vitro pilot study.

Yuan Zhou, Lang You, Zhen Fan

Abstract read
In one paragraph

Article in BMC oral health, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. [Accuracy of Conventional and Digital Impressions for Complete-Arch Implant-Supported Restorations].Sichuan da xue xue bao. Yi xue ban = Journal of Sichuan University. Medical science edition · 2025
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Yuan Zhou *Shanghai Xuhui District Dental Center, Shanghai, China.
Lang You *Shanghai Engineering Research Center of Tooth Restoration and Regeneration & Tongji Research Institute of Stomatology & Department of Implantology, Stomatological Hospital, Dental School, Tongji University, Shanghai, China.
Zhen FanShanghai Engineering Research Center of Tooth Restoration and Regeneration & Tongji Research Institute of Stomatology & Department of Implantology, Stomatological Hospital, Dental School, Tongji University, Shanghai, China. miss.fanzhen@tongji.edu.cn.

Funding

National Key Research and Development Program of China 2021YFC2400400Scientific Research Project of Shanghai Municipal Health Commission 202040094
6 · The paper itself

Abstract

backgroundIn edentulous jaws, factors such as the number of implants, cross-arch distribution, and the angle among implants may affect the accuracy of the implant impression. This study explored factors influencing the accuracy of implant abutment-level digital impressions using stereophotogrammetry in edentulous jaws.

methodsTwo standard all-on-4 and all-on-6 models of edentulous jaws were constructed in vitro. In the stereophotogrammetry group (PG), the implant digital impression was made using stereophotogrammetry and saved as an STL file. In the conventional group (CNV), the impression was made using the open-tray splint impression technique. An electronic and optical 3D measuring instrument was used to scan the standard model and the conventional plaster model to obtain STL files. Using 3D data processing software (GOM Inspect Pro, Zeiss), the distance and angle between the abutments in the CNV impression and the PG impression were measured and compared with the data from the standard model.

resultsThe distance deviation in the PG and the CNV was 145 ± 196 μm and 96 ± 150 μm, respectively, with a significant difference (P < 0.001). The angle deviation in the PG and the CNV was 0.82 ± 0.88° and 0.74 ± 0.62°, respectively, with no significant difference (P = 0.267). In the PG, the distance deviation was negatively correlated with the distance between implants (r = -0.145, P = 0.028) and positively correlated with the angle of implants (r = 0.205, P = 0.002). The angle deviation was negatively correlated with the distance between implants (r = -0.198, P = 0.003) and positively correlated with the angle of implants (r = 0.172, P = 0.009). In the CNV, the effect of inter-implant distance on impression accuracy was also shown by Spearman correlation analysis: r = 0.347 (P < 0.001) for distance deviation and r = -0.012 (P = 0.859) for angle deviation. The effect of inter-implant angulation on impression accuracy deviation was r = -0.026 (P = 0.698) for distance deviation and r = 0.056 (P = 0.399) for angle deviation.

conclusionsThe CNV method is closer to the real value of the original model. The distance between implants and the distribution angle had a weak correlation with the accuracy of digital impressions but no significant correlation with the accuracy of traditional impressions.

Indexed as

Dental Impression TechniqueImaging, Three-DimensionalJaw, EdentulousPhotogrammetryComputer-Aided DesignDental AbutmentsDental Implant-Abutment DesignDental ImplantsHumansIn Vitro TechniquesModels, DentalPilot ProjectsDental ImplantsAccuracyConventional impressionDigital impressionEdentulousStereophotogrammetry

Identifiers

PMID39354443
PMCPMC11443943

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.