ArticleAnnals of nuclear medicine2025
A Monte Carlo study comparing dead-time losses of a gamma camera between tungsten functional paper and lead sheet for dosimetry in targeted radionuclide therapy with Lu-177.
Article in Annals of nuclear medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
objectiveDead-time loss is reported to be non-negligible for some patients with a high tumor burden in Lu-177 radionuclide therapy, even if the administered activity is 7.4 GBq. Hence, we proposed a simple method to shorten the apparent dead time and reduce dead-time loss using a thin lead sheet in previous work. The collimator surface of the gamma camera was covered with a lead sheet in our proposed method. While allowing the detection of 208-keV gamma photons of Lu-177 that penetrate the sheet, photons with energies lower than 208 keV, which cause dead-time loss, were shielded. In this study, we evaluated the usefulness of tungsten functional paper (TFP) for the proposed method using Monte Carlo simulation.
methodsThe count rates in imaging of Lu-177 administered to patients were simulated with the International Commission on Radiological Protection (ICRP) 110 phantom using the GATE Monte Carlo simulation toolkit. The simulated gamma cameras with a 0.5-mm lead sheet, 1.2-mm TFP, or no filter were positioned closely on the anterior and posterior sides of the phantom. The apparent dead times and dead-time losses at 24 h after administration were calculated for an energy window of 208 keV ± 10%. Moreover, the dead-time losses at 24-120 h were analytically assessed using activity excretion data of Lu-177-DOTATATE.
resultsThe dead-time loss without a filter was 5% even 120 h after administration in patients with a high tumor burden and slow excretion, while those with a lead sheet and TFP were 0.22 and 0.58 times less than those with no filter, respectively. The count rates with the TFP were 1.3 times higher than those with the lead sheet, and the TFP could maintain primary count rates at 91-94% of those without a filter.
conclusionsAlthough the apparent dead time and dead-time loss with the lead sheet were shorter and less than those with TFP, those with TFP were superior to those without a filter. The advantage of TFP over the lead sheet is that the decrease in primary count rates was less.