ArticleAAPS PharmSciTech2024
An Exploration of Dissolution Tests for Inhalation Aerosols.
Article in AAPS PharmSciTech, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study aimed to establish a feasible dissolution method for inhalation aerosols. A method of collecting fine particles was investigated to capture aerosol particles less than 4 μm in diameter for dissolution tests. This dose collection method enabled the aerosol particles to be uniformly distributed on the glass fiber filter, thus considerably reducing particle agglomeration. Budesonide was used as a model drug. The aerodynamic particle size distribution (APSD) of the meter-dose inhaler (MDI) was compared by replacing actuators with different orifice sizes. Dissolution tests were conducted on fine particle doses collected using various actuators, and the dissolution profiles were modeled. The fine particle dose decreased with an increasing orifice size of the actuator. Actuators with different orifice sizes would affect the dissolution behavior of inhaled drugs. This finding was supported by similarity factor f
Indexed as
Identifiers
39354249What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.