Evidence map›Paper›PMID 39351580›Full record

ArticleJournal of experimental orthopaedics2024

Intra-rater and inter-rater reliability of robotic arthrometer DYNEELAX®.

Katja Mihalinec, Carmen B Martinez-Cepa, Juan C Zuil-Escobar, Nataša Kejžar, Renata Vauhnik

Abstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Katja MihalinecDepartment of Physiotherapy Biomechanical Laboratory, Faculty of Health Sciences, University of Ljubljana Ljubljana Slovenia.ORCID 0009-0007-5074-8921
Carmen B Martinez-CepaDepartamento de Fisioterapia Facultad de Medicina, Urbanización Montepríncipe, Universidad San Pablo-CEU, CEU Universities Boadilla del Monte Spain.ORCID https://orcid.org/0000-0002-9081-2752
Juan C Zuil-EscobarDepartamento de Fisioterapia Facultad de Medicina, Urbanización Montepríncipe, Universidad San Pablo-CEU, CEU Universities Boadilla del Monte Spain.ORCID https://orcid.org/0000-0002-4425-7911
Nataša KejžarFaculty of Medicine, Institute for Biostatistics and Medical Informatics University of Ljubljana Ljubljana Slovenia.ORCID 0000-0003-3069-9863
Renata VauhnikDepartment of Physiotherapy Biomechanical Laboratory, Faculty of Health Sciences, University of Ljubljana Ljubljana Slovenia.ORCID 0000-0003-0543-4919

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: The purpose of our study was to test the intra-rater and inter-rater reliability of the DYNEELAX® arthrometer in healthy subjects. Since rotational laxity will be measured for the first time in humans, indications for normative values will also be presented. Methods: Knee anterior laxity and rotational laxity using a DYNEELAX® arthrometer were assessed in 73 subjects (39 females and 34 males). An intraclass correlation coefficient was calculated to evaluate the intra-rater and inter-rater reliability of the DYNEELAX®. Results: An intraclass correlation coefficient for intra-rater reliability ranges from 0.631 (95% confidence interval; [CI]: 0.47-0.75) to 0.699 (95% CI: 0.56-0.80) and from 0.916 (95% CI: 0.87-0.95) to 0.94 (95% CI: 0.91-0.96) for anterior knee laxity and rotational knee laxity, respectively. An intraclass correlation coefficient for inter-rater reliability ranges from 0.578 (95% CI: 0.40-0.71) to 0.646 (95% CI: 0.44-0.78) and from 0.822 (95% CI: 0.57-0.91) to 0.933 (95% CI: 0.89-0.96) for anterior knee laxity and rotational knee laxity, respectively. Conclusions: The DYNEELAX® arthrometer has good to excellent intra-rater and inter-rater reliability for rotational knee laxity and moderate intra-rater reliability for anterior knee laxity in healthy subjects. Future studies should investigate the clinical significance of anterior and rotational laxity measured with the DYNEELAX® arthrometer in patients with knee pathology, as both laxities are critical for assessing the integrity of the intra-articular structures of the knee in clinical practice. Level of evidence: Level IV.

Indexed as

anterior laxityarthrometryreliabilityrotational laxity

Identifiers

PMID39351580
PMCPMC11440140

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.