Evidence map›Paper›PMID 39351507›Full record

ArticleTrauma case reports2024

Secondary removal of intramedullary metal debris from a defective Reamer-Irrigator-Aspirator (RIA) reamer head: A case report.

Philipp Vetter, Christian Hübner, Sandro-Michael Heining, Christian Hierholzer, Hans-Christoph Pape

Abstract readCase Reports
In one paragraph

Article in Trauma case reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Philipp VetterDepartment of Trauma Surgery, University Hospital Zurich, Raemistrasse 100, 8091 Zurich, Switzerland.
Christian HübnerDepartment of Trauma Surgery, University Hospital Zurich, Raemistrasse 100, 8091 Zurich, Switzerland.
Sandro-Michael HeiningDepartment of Trauma Surgery, University Hospital Zurich, Raemistrasse 100, 8091 Zurich, Switzerland.
Christian HierholzerDepartment of Trauma Surgery, University Hospital Zurich, Raemistrasse 100, 8091 Zurich, Switzerland.
Hans-Christoph PapeDepartment of Trauma Surgery, University Hospital Zurich, Raemistrasse 100, 8091 Zurich, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The Reamer-Irrigator-Aspirator (RIA) device represents a safe and efficient method to harvest autologous bone for grafting. However, hardware failure may occur, for example by breakage of the reamer head with metal debris remaining in the intramedullary canal. This case report describes the uncomplicated secondary removal of femoral intramedullary metal debris from a broken RIA reamer head; three weeks after the final surgery of a two-stage Masquelet procedure for the treatment of posttraumatic segmental bone loss at the tibia.

Indexed as

BoneReamerTrauma

Identifiers

PMID39351507
PMCPMC11440285

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked