Evidence map›Paper›PMID 39351211›Full record

ArticleJournal of vascular surgery cases and innovative techniques2024

Biodesign: Engineering an aortic endograft explantation tool.

Solyman Hatami, Vamsi Maturi, Alwin Mathew, Shannon Lu, Paul Haddad, Daanish Sheikh, Maham Rahimi

Abstract read
In one paragraph

Article in Journal of vascular surgery cases and innovative techniques, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Biodesign: Engineering an aortic endograft explantation tool.Journal of vascular surgery cases and innovative techniques · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Solyman HatamiTexas A&M School of Engineering Medicine, Houston, TX.
Vamsi MaturiTexas A&M School of Engineering Medicine, Houston, TX.
Alwin MathewTexas A&M School of Engineering Medicine, Houston, TX.
Shannon LuTexas A&M School of Engineering Medicine, Houston, TX.
Paul HaddadDepartment of Cardiovascular Surgery, Houston Methodist, Houston, TX.
Daanish SheikhUTHSCSA Long School of Medicine, San Antonio, TX.
Maham RahimiDepartment of Cardiovascular Surgery, Houston Methodist, Houston, TX.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Endovascular aortic repair (EVAR) graft failure can be as high as 16% to 30% owing to endoleak, graft migration, or infection, often necessitating explantation, leading to potential morbidity (31%) and mortality (6.3%). Graft prongs frequently tear through the endothelium during explantation, leading to endothelial damage and subsequent fatal bleeding. The current standard of care involves different suboptimal techniques such as the syringe technique in which a cylinder is improvised by cutting a syringe in half and pushed over the graft hooks in a rotating motion, until covered for manual explantation. Because there is no commercially available product to address this shortcoming in graft explantation, we engage in the biodesign process to produce a functional explantation device. We designed and prototyped multiple potential solutions to remove EVAR endografts safely. Silicone tubing with EVAR endografts deployed in the lumen were used to simulate a grafted aorta and test each prototype. Prototypes were compared in their ability to meet design criteria including decrease in graft diameter, prevention of arterial dissection, ease of use, and decrease in procedure time. After determining the single best prototype, surgeon feedback was elicited to iteratively improve the original design. The most effective design uses a tapered lumenal geometry that decreases the EVAR graft diameter and uses stainless steel beads to prevent shear stress to the simulated aorta. A distal grip allows for easy single hand manipulation of the device, while a latching mechanism allows for smooth placement and removal over the endograft. After rigorous prototyping, our device proved feasible and effective for safe EVAR explantation, allowing this procedure to be performed safely.

Indexed as

Abdominal aortic aneurysmAortic graft infectionBiomedical innovationEVAR explantationOpen endograft explantation

Identifiers

PMID39351211
PMCPMC11439838

What OpenQuestion holds