Evidence map›Paper›PMID 39350209›Full record

ArticleArthroplasty (London, England)2024

Unveiling the dynamics of intraoperative contamination in total hip arthroplasty: the discrepancy between particulate and microbial contamination in surgical site infection risk.

Toshiyuki Tateiwa, Toshinori Masaoka, Yasuhito Takahashi, Tsunehito Ishida, Takaaki Shishido, Kengo Yamamoto

Abstract read
In one paragraph

Article in Arthroplasty (London, England), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Toshiyuki TateiwaDepartment of Orthopedic Surgery, Tokyo Medical University, 6-7-1, Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan. tateiwa@tokyo-med.ac.jp.ORCID http://orcid.org/0000-0002-2693-3576
Toshinori MasaokaDepartment of Orthopedic Surgery, Tokyo Medical University, 6-7-1, Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan.
Yasuhito TakahashiDepartment of Orthopedic Surgery, Tokyo Medical University, 6-7-1, Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan.
Tsunehito IshidaDepartment of Orthopedic Surgery, Tokyo Medical University, 6-7-1, Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan.
Takaaki ShishidoDepartment of Orthopedic Surgery, Tokyo Medical University, 6-7-1, Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan.
Kengo YamamotoDepartment of Orthopedic Surgery, Tokyo Medical University, 6-7-1, Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSurgical site infection (SSI) is a major problem following total hip arthroplasty (THA). This study investigated the impact of a standard intraoperative routine where the surgical team wears full-body exhaust suits (space suits) within a laminar airflow (LAF)-ventilated operating room (OR) on environmental contamination. Our primary objective was to identify potential modifiable intraoperative factors that could be better controlled to minimize SSI risk.

methodsWe implemented an approach involving simultaneous and continuous air sampling throughout actual primary cementless THA procedures. This method concurrently monitored both airborne particle and microbial contamination levels from the time the patient entered the OR for surgery until extubation.

resultsAirborne particulate and microbial contamination significantly increased during the first and second patient repositionings (postural changes) when the surgical team was not wearing space suits. However, their concentration exhibited inconsistent changes during the core surgical procedures, between incision and suturing, when the surgeons wore space suits. The microbial biosensor detected zero median microbes from draping to suturing. In contrast, the particle counter indicated a significant level of airborne particles during head resection and cup press-fitting, suggesting these procedures might generate more non-viable particles.

conclusionsThis study identified a significant portion of airborne particles during the core surgical procedures as non-viable, suggesting that monitoring solely for particle counts might not suffice to estimate SSI risk. Our findings strongly support the use of space suits for surgeons to minimize intraoperative microbial contamination within LAF-ventilated ORs. Therefore, minimizing unnecessary traffic and movement of unsterile personnel is crucial. Additionally, since our data suggest increased contamination during patient repositioning, effectively controlling contamination during the first postural change plays a key role in maintaining low microbial contamination levels throughout the surgery. The use of sterile gowns during this initial maneuver might further reduce SSIs. Further research is warranted to investigate the impact of sterile attire on SSIs.

Indexed as

Microbial contaminationParticle contaminationSpace suitsSurgical site infectionTotal hip arthroplasty

Identifiers

PMID39350209
PMCPMC11443724

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.