Evidence map›Paper›PMID 39347545›Full record

ArticleJournal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine2025

Optimizing wearable single-channel electroencephalography sleep staging in a heterogeneous sleep-disordered population using transfer learning.

Jaap F van der Aar, Merel M van Gilst, Daan A van den Ende, Pedro Fonseca, Bregje N J van Wetten, Hennie C J P Janssen, Elisabetta Peri, Sebastiaan Overeem

Abstract read
In one paragraph

Article in Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jaap F van der AarDepartment of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
Merel M van GilstDepartment of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
Daan A van den EndePhilips Innovation & Strategy, Department of Innovation Engineering, Philips, Eindhoven, The Netherlands.
Pedro FonsecaDepartment of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
Bregje N J van WettenCenter for Sleep Medicine Kempenhaeghe, Heeze, The Netherlands.
Hennie C J P JanssenCenter for Sleep Medicine Kempenhaeghe, Heeze, The Netherlands.
Elisabetta PeriDepartment of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
Sebastiaan OvereemDepartment of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

STUDY

objectivesAlthough various wearable electroencephalography devices have been developed, performance evaluation of the devices and their associated automated sleep stage classification models is mostly limited to healthy participants. A major barrier for applying automated wearable electroencephalography sleep staging in clinical populations is the need for large-scale data for model training. We therefore investigated transfer learning as a strategy to overcome limited data availability and optimize automated single-channel electroencephalography sleep staging in people with sleep disorders.

methodsWe acquired 52 single-channel frontopolar headband electroencephalography recordings from a heterogeneous sleep-disordered population with concurrent polysomnography (PSG). We compared 3 model training strategies: "pretraining" (ie, training on a larger dataset of 901 conventional PSGs), "training-from-scratch" (ie, training on wearable headband recordings), and "fine-tuning" (ie, training on conventional PSGs, followed by training on headband recordings). Performance was evaluated on all headband recordings using 10-fold cross-validation.

resultsHighest performance for 5-stage classification was achieved with fine-tuning (κ = .778), significantly higher than with pretraining (κ = .769) and with training-from-scratch (κ = .733). No significant differences or systematic biases were observed with clinically relevant sleep parameters derived from PSG. All sleep disorder categories showed comparable performance.

conclusionsThis study emphasizes the importance of leveraging larger available datasets through deep transfer learning to optimize performance with limited data availability. Findings indicate strong similarity in data characteristics between conventional PSG and headband recordings. Altogether, results suggest the combination of the headband, classification model, and training methodology can be viable for sleep monitoring in the heterogeneous clinical population. CITATION: van der Aar JF, van Gilst MM, van den Ende DA, et al. Optimizing wearable single-channel electroencephalography sleep staging in a heterogeneous sleep-disordered population using transfer learning.

Indexed as

ElectroencephalographySleep StagesSleep Wake DisordersWearable Electronic DevicesAdultFemaleHumansMaleMiddle AgedPolysomnographysingle-channelsleep disorderssleep stagingtransfer learningwearable EEG

Identifiers

PMID39347545
PMCPMC11789263

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.