Evidence map›Paper›PMID 39346784›Full record

ArticleLaryngoscope investigative otolaryngology2024

A MAUDE database analysis on the new generation of active bone conduction hearing implants.

Alexander Lein, Wolf-Dieter Baumgartner, Lukas D Landegger, Dominik Riss, Thomas Thurner, David T Liu, Andro Kosec, Erich Vyskocil, Faris F Brkic

Abstract read
In one paragraph

Article in Laryngoscope investigative otolaryngology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Guideline
  2. Article
  3. Hearing Rehabilitation with OsiaYonsei medical journal · 2025
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Alexander LeinDepartment of Otorhinolaryngology, Head and Neck Surgery Medical University of Vienna Vienna Austria.ORCID https://orcid.org/0000-0002-9912-9837
Wolf-Dieter BaumgartnerDepartment of Otorhinolaryngology, Head and Neck Surgery Medical University of Vienna Vienna Austria.
Lukas D LandeggerDepartment of Otorhinolaryngology, Head and Neck Surgery Medical University of Vienna Vienna Austria.
Dominik RissDepartment of Otorhinolaryngology, Head and Neck Surgery Medical University of Vienna Vienna Austria.
Thomas ThurnerDepartment of Otorhinolaryngology, Head and Neck Surgery Medical University of Vienna Vienna Austria.
David T LiuDepartment of Otorhinolaryngology, Head and Neck Surgery Medical University of Vienna Vienna Austria.ORCID https://orcid.org/0000-0001-6948-737X
Andro KosecDepartment of Otorhinolaryngology, Head and Neck Surgery University Clinical Hospital Center Sestre Milosrdnice Zagreb Croatia.ORCID https://orcid.org/0000-0001-7864-2060
Erich VyskocilDepartment of Otorhinolaryngology, Head and Neck Surgery Medical University of Vienna Vienna Austria.ORCID https://orcid.org/0000-0003-1458-9824
Faris F BrkicDepartment of Otorhinolaryngology, Head and Neck Surgery Medical University of Vienna Vienna Austria.ORCID https://orcid.org/0000-0002-0770-6677

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To analyze medical device reports (MDR) submitted to the Food and Drug Administration's (FDA) Manufacturer and User Device Facility Experience (MAUDE) database to identify adverse events (AEs) in patients implanted with novel active bone conduction hearing implants (BCIs). Methods: We conducted a search of the FDA MAUDE database on the newest generation of BCIs. Data were collected concerning device malfunctions, patient injuries, factors triggering these incidents, and the subsequent actions taken. Results: In total, 93 (16.7%) device malfunctions and 465 (83.3%) patient injuries with 358 subsequent interventions were identified, resulting in 558 AEs. Although the absolute AE number per device cannot be identified, the following trends were detected: Among the 494 AEs associated with OSI200, 55 (11.1%) reported device malfunctions and 454 (88.9%) cited patient injuries. Out of the 64 AEs linked to BCI602, 28 (59.4%) were associated with malfunctions, whereas 26 (40.6%) involved patient injuries. The most frequently reported particular AEs for the OSI200 were infection ( Conclusion: The current study provides an overview of the most commonly reported complications with new active BCIs. Although providing an overview, given the limitations of the FDA MAUDE database, our results have to be interpreted with caution. Level of Evidence: 4.

Indexed as

BCI602bone‐anchored hearing aidscomplicationsMAUDE databaseOSI200

Identifiers

PMID39346784
PMCPMC11437528

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.