Evidence map›Paper›PMID 39345264›Full record

ArticleJournal of orthopaedics2025

Independent volumetric internal fixation reduces posterior column acetabular fracture site motion as compared to plate/screw construct: A biomechanical analysis.

Helyn G Fraser, M Wesley Honeycutt, Daniel Thompson, Nina Suh, Huai Ming Phen, William S Godfrey, Adam R Boissoneault, Michael A Maceroli

Abstract read
In one paragraph

Article in Journal of orthopaedics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Helyn G FraserEmory University Department of Orthopaedic Surgery, USA.
M Wesley HoneycuttSan Antonio Military Medical Center Department of Orthopaedic Surgery, USA.
Daniel ThompsonEmory University Department of Orthopaedic Surgery, USA.
Nina SuhEmory University Department of Orthopaedic Surgery, USA.
Huai Ming PhenEmory University Department of Orthopaedic Surgery, USA.
William S GodfreyEmory University Department of Orthopaedic Surgery, USA.
Adam R BoissoneaultEmory University Department of Orthopaedic Surgery, USA.
Michael A MaceroliEmory University Department of Orthopaedic Surgery, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aims & objectives: To establish whether a suprapectineal pelvic reconstruction plate and posterior column screw (P&S) construct or a single 6.5-mm cannulated posterior column screw (PCS) construct demonstrates greater mechanical stability for fixation of acetabulum fractures involving the posterior column (PC). We hypothesized that the PCS construct would result in less fracture site motion. Materials & methods: Twelve fourth-generation composite hemipelvi were utilized, 6 for each construct. The P&S construct consisted of a suprapectineal pelvic reconstruction plate with two 3.5-mm posterior column screws crossing the fracture site in lag-by-technique fashion and two screws anchoring the plate to the sciatic buttress. The PCS construct consisted of a single 6.5-mm partially threaded cannulated screw placed in an antegrade fashion. Both fixation models were cyclically loaded at 0.5 cycles/second at 400N and 800N, first in a sit-to-stand position that is expected during recovery, and subsequently in a squat-to-stand position to test overload conditions. Results: Under sit-to-stand loading, the PCS construct resulted in less motion at the fracture site than the P&S construct (0.06 ± 0.02 mm vs 0.1 ± 0.02 mm at 400N, p = 0.02; 0.13 ± 0.03 mm vs 0.19 ± 0.04 mm at 800N, p = 0.03). The PCS construct also demonstrated less fracture site motion under squat-to-stand loading (0.22 ± 0.13 mm vs 1.9 ± 0.5 mm at 400N, p = < 0.001; 1.48 ± 0.44 mm vs 4.77 ± 0.3 mm at 800N, p = < 0.001). At 800 N, half of the repairs failed during squat-to-stand loading (2 PCS, 4 P&S). Conclusion: Fixation of the posterior column of the acetabulum with a 6.5-mm cannulated screw demonstrated comparable fracture motion upon loading compared to the plate and screw construct.

Indexed as

Acetabulum fractureBiomechanicsCannulated screwPelvic reconstruction platePosterior column

Identifiers

PMID39345264
PMCPMC11424759

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials