Evidence map›Paper›PMID 39341832›Full record

ArticleLight, science & applications2024

Miniaturized on-chip spectrometer enabled by electrochromic modulation.

Menghan Tian, Baolei Liu, Zelin Lu, Yao Wang, Ze Zheng, Jiaqi Song, Xiaolan Zhong, Fan Wang

Abstract read
In one paragraph

Article in Light, science & applications, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Electrically Coded Retinomorphic Spectrophotodetector.Advanced materials (Deerfield Beach, Fla.) · 2026
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Menghan Tian *School of Physics, Beihang University, Beijing, 100191, China.
Baolei Liu *School of Physics, Beihang University, Beijing, 100191, China. liubaolei@buaa.edu.cn.ORCID http://orcid.org/0000-0002-4779-4683
Zelin LuSchool of Physics, Beihang University, Beijing, 100191, China.
Yao WangSchool of Physics, Beihang University, Beijing, 100191, China.
Ze ZhengSchool of Physics, Beihang University, Beijing, 100191, China.ORCID http://orcid.org/0009-0006-0321-1833
Jiaqi SongSchool of Physics, Beihang University, Beijing, 100191, China.
Xiaolan ZhongSchool of Physics, Beihang University, Beijing, 100191, China. zhongxl@buaa.edu.cn.ORCID http://orcid.org/0000-0003-4819-0416
Fan WangSchool of Physics, Beihang University, Beijing, 100191, China. fanwang@buaa.edu.cn.ORCID http://orcid.org/0000-0001-7403-3305

Funding

China Postdoctoral Science Foundation 2022M720347National Natural Science Foundation of China (National Science Foundation of China) 11804018National Natural Science Foundation of China (National Science Foundation of China) 62075004National Natural Science Foundation of China (National Science Foundation of China) 62275010National Natural Science Foundation of China (National Science Foundation of China) U23A20481Natural Science Foundation of Beijing Municipality (Beijing Natural Science Foundation) 1232027
6 · The paper itself

Abstract

Miniaturized on-chip spectrometers with small footprints, lightweight, and low cost are in great demand for portable optical sensing, lab-on-chip systems, and so on. Such miniaturized spectrometers are usually based on engineered spectral response units and then reconstruct unknown spectra with algorithms. However, due to the limited footprints of computational on-chip spectrometers, the recovered spectral resolution is limited by the number of integrated spectral response units/filters. Thus, it is challenging to improve the spectral resolution without increasing the number of used filters. Here we present a computational on-chip spectrometer using electrochromic filter-based computational spectral units that can be electrochemically modulated to increase the efficient sampling number for higher spectral resolution. These filters are directly integrated on top of the photodetector pixels, and the spectral modulation of the filters results from redox reactions during the dual injection of ions and electrons into the electrochromic material. We experimentally demonstrate that the spectral resolution of the proposed spectrometer can be effectively improved as the number of applied voltages increases. The average difference of the peak wavelengths between the reconstructed and the reference spectra decreases from 1.61 nm to 0.29 nm. We also demonstrate the proposed spectrometer can be worked with only four or two filter units, assisted by electrochromic modulation. In addition, we also demonstrate that the electrochromic filter can be easily adapted for hyperspectral imaging, due to its uniform transparency. This strategy suggests a new way to enhance the performance of miniaturized spectrometers with tunable spectral filters for high resolution, low-cost, and portable spectral sensing, and would also inspire the exploration of other stimulus responses such as photochromic and force-chromic, etc, on computational spectrometers.

Identifiers

PMID39341832
PMCPMC11438984

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.