Evidence map›Paper›PMID 39340632›Full record

ArticleOphthalmology and therapy2024

High-Tech Parameters for the Evaluation of Signs and Symptoms of Dry Eye Disease: Identification of Clinical Cut-Offs and Agreement with Low-Tech Tests.

Paolo Fogagnolo, Pasquale Aragona, Alfonso Strianese, Edoardo Villani, Giuseppe Giannaccare, Vincenzo Orfeo, Valentina Mirisola, Rita Mencucci, Italian Dry Eye Study Group

Abstract read
In one paragraph

Article in Ophthalmology and therapy, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Paolo FogagnoloHealth Sciences Department, University of Milan, Milan, Italy. paolo.fogagnolo@unimi.it.
Pasquale AragonaSection of Ophthalmology, Department of Biochemical Sciences, University of Messina, Messina, Italy.
Alfonso StrianeseEye Clinic, ASST Santi Paolo E Carlo, University of Milan, Milan, Italy.
Edoardo VillaniDepartment of Clinical Science and Community Health, University of Milan, Milan, Italy.
Giuseppe GiannaccareDepartment of Ophthalmology, University Magna Graecia of Catanzaro, Catanzaro, Italy.
Vincenzo OrfeoUnità Operativa di Oculistica Clinica Mediterranea, Naples, Italy.
Valentina MirisolaPolistudium SRL, Milan, Italy.
Rita MencucciDepartment of Neurosciences, Psychology, Drug Research, and Child Health, Eye Clinic, University of Florence, AOU Careggi, Florence, Italy.
Italian Dry Eye Study Group

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionHigh-tech devices for the assessment of dry eye disease (DED) are increasingly available. However, the agreement between high- and low-tech parameters has been poorly explored to date. Trying to fill these gaps, we conducted a post hoc analysis on a recently published retrospective study on patients with DED receiving both low- and high-tech (Keratograph

methodsSix clinical questions were defined by the authors, considering literature gaps and their clinical experience, namely: (1) are NIKBUT-i and T-BUT interchangeable parameters? (2) What was the correlation between low- and high-tech parameters in untreated and treated patients with DED? (3) What was the correlation between signs and symptoms at baseline and during/after treatment? (4) Which parameters were better associated with symptoms? And with symptoms change over time? (5) What was the performance of NIKBUT-i and T-BUT in detecting clinically relevant changes? (6) What was the clinical advantage of adding other high- and low-tech parameters, respectively, to NIKBUT-i and T-BUT?

resultsLow-tech measures were the best descriptors of the Ocular Surface Disease Index (OSDI) at baseline. In contrast, high-tech assessments demonstrate better performance in detecting changes over time. The distribution of NIKBUT-i data was more dispersed than TBUT both at baseline and follow-up. At a fixed specificity of 80%, the sensitivity in detecting clinically relevant ameliorations of symptoms was 42% for NIKBUT-i and 25% for T-BUT. A battery of high-tech tests could detect 90% of clinical amelioration, compared with 45% with low-tech tests (p < 0.001). Correlation between low- and high-tech parameters in both treated and untreated patients is lacking.

conclusionsLow-tech measures are adequate for diagnostic purposes in DED, whereas high-tech showed better performances at follow-up, particularly when different tests are combined. Overall, poor interchangeability among parameters and agreement with symptoms was reported both with high- and low-tech assessments.

Indexed as

Break-up timeDry eye diseaseHigh-tech imagingTear film instability

Identifiers

PMID39340632
PMCPMC11494620

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.