Evidence map›Paper›PMID 39338796›Full record

ArticleSensors (Basel, Switzerland)2024

Optimization of the Pixel Design for Large Gamma Cameras Based on Silicon Photomultipliers.

Carolin Wunderlich, Riccardo Paoletti, Daniel Guberman

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Carolin WunderlichIstituto Nazionale di Fisica Nucleare (INFN), Sezione di Pisa, 56126 Pisa, Italy.ORCID 0000-0002-9604-7836
Riccardo PaolettiIstituto Nazionale di Fisica Nucleare (INFN), Sezione di Pisa, 56126 Pisa, Italy.ORCID 0000-0003-0158-2826
Daniel GubermanDepartament de Física Quàntica i Astrofísica (FQA), Universitat de Barcelona (UB), 08028 Barcelona, Spain.ORCID 0000-0002-9636-1825

Funding

Agencia Estatal de Investigación Reial decret 289/2021
6 · The paper itself

Abstract

Most single-photon emission computed tomography (SPECT) scanners employ a gamma camera with a large scintillator crystal and 50-100 large photomultiplier tubes (PMTs). In the past, we proposed that the weight, size and cost of a scanner could be reduced by replacing the PMTs with large-area silicon photomultiplier (SiPM) pixels in which commercial SiPMs are summed to reduce the number of readout channels. We studied the feasibility of that solution with a small homemade camera, but the question on how it could be implemented in a large camera remained open. In this work, we try to answer this question by performing Geant4 simulations of a full-body SPECT camera. We studied how the pixel size, shape and noise could affect its energy and spatial resolution. Our results suggest that it would be possible to obtain an intrinsic spatial resolution of a few mm FWHM and an energy resolution at 140 keV close to 10%, even if using pixels more than 20 times larger than standard commercial SiPMs of 6 × 6 mm2. We have also found that if SiPMs are distributed following a honeycomb structure, the spatial resolution is significantly better than if using square pixels distributed in a square grid.

Indexed as

gamma cameralarge-area SiPMsilicon photomultiplier (SiPM)SPECT

Identifiers

PMID39338796
PMCPMC11435885

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.