Evidence map›Paper›PMID 39338640›Full record

ArticleSensors (Basel, Switzerland)2024

Remotely Powered Two-Wire Cooperative Sensors for Bioimpedance Imaging Wearables.

Olivier Chételat, Michaël Rapin, Benjamin Bonnal, André Fivaz, Benjamin Sporrer, James Rosenthal, Josias Wacker

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Olivier ChételatMedtech Business Unit, Swiss Center for Electronics and Microtechnology (CSEM), Jaquet-Droz 1, 2002 Neuchâtel, Switzerland.
Michaël RapinMedtech Business Unit, Swiss Center for Electronics and Microtechnology (CSEM), Jaquet-Droz 1, 2002 Neuchâtel, Switzerland.
Benjamin BonnalMedtech Business Unit, Swiss Center for Electronics and Microtechnology (CSEM), Jaquet-Droz 1, 2002 Neuchâtel, Switzerland.ORCID 0009-0004-2237-0560
André FivazMedtech Business Unit, Swiss Center for Electronics and Microtechnology (CSEM), Jaquet-Droz 1, 2002 Neuchâtel, Switzerland.ORCID 0009-0004-5908-5675
Benjamin SporrerIntegrated & Wireless Business Unit, Swiss Center for Electronics and Microtechnology (CSEM), Technopark, Technoparkstrasse 1, 8005 Zürich, Switzerland.ORCID 0000-0002-9892-9357
James RosenthalMedtech Business Unit, Swiss Center for Electronics and Microtechnology (CSEM), Jaquet-Droz 1, 2002 Neuchâtel, Switzerland.
Josias WackerMedtech Business Unit, Swiss Center for Electronics and Microtechnology (CSEM), Jaquet-Droz 1, 2002 Neuchâtel, Switzerland.

Funding

European Union 825572
6 · The paper itself

Abstract

Bioimpedance imaging aims to generate a 3D map of the resistivity and permittivity of biological tissue from multiple impedance channels measured with electrodes applied to the skin. When the electrodes are distributed around the body (for example, by delineating a cross section of the chest or a limb), bioimpedance imaging is called electrical impedance tomography (EIT) and results in functional 2D images. Conventional EIT systems rely on individually cabling each electrode to master electronics in a star configuration. This approach works well for rack-mounted equipment; however, the bulkiness of the cabling is unsuitable for a wearable system. Previously presented cooperative sensors solve this cabling problem using active (dry) electrodes connected via a two-wire parallel bus. The bus can be implemented with two unshielded wires or even two conductive textile layers, thus replacing the cumbersome wiring of the conventional star arrangement. Prior research demonstrated cooperative sensors for measuring bioimpedances, successfully realizing a measurement reference signal, sensor synchronization, and data transfer though still relying on individual batteries to power the sensors. Subsequent research using cooperative sensors for biopotential measurements proposed a method to remove batteries from the sensors and have the central unit supply power over the two-wire bus. Building from our previous research, this paper presents the application of this method to the measurement of bioimpedances. Two different approaches are discussed, one using discrete, commercially available components, and the other with an application-specific integrated circuit (ASIC). The initial experimental results reveal that both approaches are feasible, but the ASIC approach offers advantages for medical safety, as well as lower power consumption and a smaller size.

Indexed as

Electric ImpedanceElectrodesWearable Electronic DevicesBiosensing TechniquesElectric Power SuppliesEquipment DesignHumansTomographyactive electrodebioimpedance imagingcardiopulmonary diseasescooperative sensorCOPDdry electrodeelectrical impedance tomography (EIT)medical devicerespiratory diseaseswearables

Identifiers

PMID39338640
PMCPMC11435524

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.