ArticleSensors (Basel, Switzerland)2024
Design and Analysis of a Hand-Held Surgical Forceps with a Force-Holding Function.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
Physiological hand tremors, twitching, and the nonlinear characteristics of the relationship between surgical forceps clamping force and operating force seriously affect the clamping accuracy of surgical instruments. To address this problem, a new type of surgical forceps with a force-holding function was developed to replace traditional forceps, which was studied in terms of structural design, statics, and dynamics. The overall structure of the surgical forceps was designed based on the lever principle, the kinematic model of the clamping part of the surgical forceps was established by the geometrical method, and the correctness of the kinematic model was verified by ADAMS. To address the clamping accuracy of the surgical forceps, a stress analysis was performed, its dynamics model was established, a finite element simulation was performed, the modal of the forceps was optimized using the Box-Behnken method, and, finally, an experimental platform was built to perform the accuracy test. The results demonstrate that the designed surgical forceps exhibit high clamping accuracy and fulfill the design specifications for surgical operations.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.