ArticleMaterials (Basel, Switzerland)2024
Continuous and Stable Printing Method of Planar Microstructure Based on Meniscus-Confined Electrodeposition.
Article in Materials (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
The meniscus-confined electrodeposition (MCED) technique offers advantages such as low cost and wide applicability, making it a promising method in the field of micro/nanofabrication. However, unstable meniscal morphology and poor deposition quality during planar deposition in MCED necessitate the development of improved methods. Therefore, a planar adaptive micro-tuning deposition method (PAMTDM), which utilizes the positioning technology of scanning electrochemical cell microscopy (SECCM) and employs a singular value decomposition (SVD) planar fitting method to determine the flatness of the deposition plane, is proposed. An adaptive micro-tuning motion mode was proposed by analyzing the variation patterns of the meniscus. Moreover, a combination of multi-physics finite element simulations and orthogonal experimental methods was introduced to determine the optimal motion parameters. The experimental results demonstrate that the PAMTDM effectively addresses the issues encountered during planar growth. Compared to the point-by-point deposition method, the PAMTDM achieves a threefold increase in deposition speed for continuous deposition of 105-μm-long line segments in two-dimensional planes, with a deposition current error of less than 0.2 nA. In conclusion, the proposed method provides significant insights into the broad future applications of MCED.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.