Evidence map›Paper›PMID 39334368›Full record

ArticleBMC health services research2024

Reducing catheter-related bloodstream infections using Lean Six Sigma methodology.

Xiwen Feng, Qihua Huang, Li Yuan, Fuhua Lu, Rujia Deng, Ping Xia

Abstract read
In one paragraph

Article in BMC health services research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Xiwen Feng *Department of Biostatistics and Health Data Science, School of Medicine, Indiana University, Indianapolis, IN, 46202, USA.
Qihua Huang *Nursing Department, The Second Affiliated Hospital of Guangzhou, University of Chinese Medicine, Guangzhou, Guangdong, 510120, China.
Li YuanThe Second Clinical Medical College of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, 510405, China.
Fuhua LuDepartment of Nephrology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, 510120, China.
Rujia DengDepartment of Nephrology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, 510120, China.
Ping XiaDepartment of Social Medicine and Health Management, School of Public Health, Guangdong Pharmaceutical University, Guangzhou, Guangdong, 510006, China. xiaping1976@163.com.

Funding

National Natural Science Foundation of China 72074057
6 · The paper itself

Abstract

backgroundCentral venous catheters (CVC) are used for dialysis in end-stage renal disease patients, presenting a significant risk for Catheter-Related Bloodstream Infections (CRBSI). While Lean Six Sigma has been effective in reducing CRBSI, its efficacy outside intensive care units (ICU) remains less explored. This study aims to evaluate the effectiveness of Lean Six Sigma in mitigating CRBSI risks among non-ICU hemodialysis patients.

methodsThe study was conducted in a nephrology department, focusing on patients undergoing hemodialysis with temporary CVC from February to December 2021. The Lean Six Sigma method, using Define-Measure-Analyze-Improve-Control (DMAIC) methodology, was implemented in 2022 to reduce CRBSI incidence. The 2021 CRBSI rate served as the benchmark, with a goal to reduce it by the end of 2022. Value-stream mapping, Fishbone Diagrams, and Root Cause Analysis identified potential CRBSI causes. After implementing targeted improvements, CRBSI rates before and after the intervention were compared.

resultsThe Lean Six Sigma method significantly decreased CRBSI incidence from 12.79 to 2.32 per 1,000 catheter-days following the implementation of targeted interventions ([Formula: see text]=4.60, P = 0.05). This improvement was observed comparing February-December 2021 with January-December 2022.

conclusionThe findings demonstrate the effectiveness of the Lean Six Sigma method in non-ICU settings, suggesting broader applicability in hemodialysis patient care.

Indexed as

Catheter-Related InfectionsQuality ImprovementRenal DialysisTotal Quality ManagementCatheterization, Central VenousCentral Venous CathetersFemaleHumansIncidenceKidney Failure, ChronicMaleMiddle AgedCatheter-related bloodstream infectionsDefine-measure-analyze-improve-control (DMAIC) methodologyLean Six SigmaQuality Improvement

Identifiers

PMID39334368
PMCPMC11430130

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.