Evidence map›Paper›PMID 39334124›Full record

ArticleBMC medical informatics and decision making2024

Comparison of semi and fully automated artificial intelligence driven softwares and manual system for cephalometric analysis.

Rumeesha Zaheer, Hafiza Zobia Shafique, Zahra Khalid, Rooma Shahid, Abdullah Jan, Tooba Zahoor, Ramsha Nawaz, Mehak Ul Hassan

Abstract readComparative Study
In one paragraph

Article in BMC medical informatics and decision making, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Rumeesha ZaheerArmed Forces Institute of Dentistry Rawalpindi, Rawalpindi, Pakistan.
Hafiza Zobia ShafiqueArmed Forces Institute of Dentistry Rawalpindi, Rawalpindi, Pakistan.
Zahra KhalidArmed Forces Institute of Dentistry, National University of Medical Sciences, Rawalpindi, Pakistan. zahrakhalid26@gmail.com.
Rooma ShahidArmed Forces Institute of Dentistry Rawalpindi, Rawalpindi, Pakistan.
Abdullah JanArmed Forces Institute of Dentistry, National University of Medical Sciences, Rawalpindi, Pakistan.
Tooba ZahoorArmed Forces Institute of Dentistry Rawalpindi, Rawalpindi, Pakistan.
Ramsha NawazArmed Forces Institute of Dentistry Rawalpindi, Rawalpindi, Pakistan.
Mehak Ul HassanArmed Forces Institute of Dentistry Rawalpindi, Rawalpindi, Pakistan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCephalometric analysis has been used as one of the main tools for orthodontic diagnosis and treatment planning. The analysis can be performed manually on acetate tracing sheets, digitally by manual selection of landmarks or by recently introduced Artificial Intelligence (AI)-driven tools or softwares that automatically detect landmarks and analyze them. The use of AI-driven tools is expected to avoid errors and make it less time consuming with effective evaluation and high reproducibility.

objectiveTo conduct intra- and inter-group comparisons of the accuracy and reliability of cephalometric tracing and evaluation done manually and with AI-driven tools that is WebCeph and CephX softwares.

methodsDigital and manual tracing of lateral cephalometric radiographs of 54 patients was done. 18 cephalometric parameters were assessed on each radiograph by 3 methods, manual method and by using semi (WebCeph) and fully automatic softwares (Ceph X). Each parameter was assessed by two investigators using these three methods. SPSS was then used to assess the differences in values of cephalometric variables between investigators, between softwares, between human investigator means and software means. ICC and paired T test were used for intra-group comparisons while ANOVA and post-hoc were used for inter-group comparisons.

resultsTwelve out of eighteen variables had high intra-group correlation and significant ICC p-values, 5 variables had relatively lower values and only one variable (SNO) had significantly low ICC value. Fifteen out of eighteen variables had minimal detection error using fully-automatic method of cephalometric analysis. Only three variables had lowest detection error using semi-automatic method of cephalometric analysis. Inter-group comparison revealed significant difference between three methods for eight variables; Witts, NLA, SNGoGn, Y-Axis, Jaraback, SNO, MMA and McNamara to Point A.

conclusionThere is a lack of significant difference among manual, semiautomatic and fully automatic methods of cephalometric tracing and analysis in terms of the variables measured by these methods. The mean detection errors were the highest for manual analysis and lowest for fully automatic method. Hence the fully automatic AI software has the most reproducible and accurate results.

Indexed as

Artificial IntelligenceCephalometrySoftwareAdolescentFemaleHumansMaleReproducibility of ResultsArtificial IntelligenceCephalometric analysesCephXLateral cephalogramWebCeph

Identifiers

PMID39334124
PMCPMC11428328

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.