Evidence map›Paper›PMID 39331066›Full record

ArticleInternational orthopaedics2024

Reconstruction of severe acetabular defects (Paprosky type III A) in total hip arthroplasty using modular tantalum augments in combination with a cemented cup.

David Spranz, Lisa-Marie Müller, Raphael Trefzer, Pit Hetto, Timo Nees, Tobias Renkawitz, Tilman Walker, Tobias Reiner

Abstract read
In one paragraph

Article in International orthopaedics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

David SpranzDepartment of Orthopaedics, University Hospital Heidelberg, Schlierbacher Landstraße 200a, 69118, Heidelberg, Germany.
Lisa-Marie MüllerDepartment of Orthopaedics, University Hospital Heidelberg, Schlierbacher Landstraße 200a, 69118, Heidelberg, Germany.
Raphael TrefzerDepartment of Orthopaedics, University Hospital Heidelberg, Schlierbacher Landstraße 200a, 69118, Heidelberg, Germany.
Pit HettoDepartment of Orthopaedics, University Hospital Heidelberg, Schlierbacher Landstraße 200a, 69118, Heidelberg, Germany.
Timo NeesDepartment of Orthopaedics, University Hospital Heidelberg, Schlierbacher Landstraße 200a, 69118, Heidelberg, Germany.
Tobias RenkawitzDepartment of Orthopaedics, University Hospital Heidelberg, Schlierbacher Landstraße 200a, 69118, Heidelberg, Germany.
Tilman WalkerDepartment of Orthopaedics, University Hospital Heidelberg, Schlierbacher Landstraße 200a, 69118, Heidelberg, Germany.
Tobias ReinerDepartment of Orthopaedics, University Hospital Heidelberg, Schlierbacher Landstraße 200a, 69118, Heidelberg, Germany. Tobias.Reiner@med.uni-heidelberg.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeAcetabular defect reconstruction can be a complex and challenging surgical procedure, with stable long-term fixation of the implants remaining the ultimate goal. The purpose of this study was (1) to evaluate the radiological and clinical outcome of complex acetabular reconstruction surgery with the use of modular tantalum TM augments in combination with cemented revision cups; (2) to investigate blood tantalum concentrations in these patients; and (3) to report complications and mechanisms of failure related to this procedure at mid-term follow-up (mean 4.5 years).

methodsWe retrospectively reviewed 29 patients (29 hips) with severe acetabular bone loss (Paprosky type III A) reconstructed using a modular tantalum TM augment in combination with a cemented cup. We evaluated the implant survival and the radiological and clinical outcomes after a mean follow-up of 4.5 years (SD 2.2; range 8.4 - 2.1 years) using patient reported outcome scores (PROMs). Blood samples were analysed regarding tantalum concentration and compared with a control group.

resultsThe cumulative survival rate at 4.5 years with the endpoint "revision of the acetabular component for any reason" was 96.2% (95% Confidence Interval 75.7-99.5). The PROMs improved significantly up to the latest follow-up, and radiographic data showed only one patient with signs of initial implant migration with a broken screw and a change of the position of the augment and the cup. Mean blood tantalum concentrations were significantly higher in the study group (0.16 µg/L) compared to the control group (0.002 µg/L) (P < 0.001).

conclusionsThis study has demonstrated good mid-term (mean 4.5 years) clinical and radiological outcomes of modular tantalum TM augments in combination with a cemented cup for the reconstruction of major acetabular defects. Mean blood tantalum concentrations were increased in patients with stable tantalum implants compared to healthy controls.

Indexed as

AcetabulumArthroplasty, Replacement, HipBone CementsHip ProsthesisProsthesis FailureReoperationTantalumAdultAgedAged, 80 and overFemaleFollow-Up StudiesHumansMaleMiddle AgedProsthesis DesignBone CementsTantalumAcetabular defect reconstructionHip revision arthroplastyModularityTantalum trabecular metal augmentsTotal hip arthroplasty

Identifiers

PMID39331066
PMCPMC11564221

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.