ArticleJournal of functional biomaterials2024

Modular Hemipelvic Prosthesis Preserves Normal Biomechanics and Showed Good Compatibility: A Finite Element Analysis.

Yuanrui Luo, Hongtao Sheng, Yong Zhou, Li Min, Chongqi Tu, Yi Luo

Abstract read
In one paragraph

Article in Journal of functional biomaterials, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yuanrui LuoDepartment of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu 610041, China.ORCID 0000-0001-7872-4365
Hongtao ShengDepartment of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu 610041, China.
Yong ZhouDepartment of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu 610041, China.
Li MinDepartment of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu 610041, China.
Chongqi TuDepartment of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu 610041, China.
Yi LuoDepartment of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu 610041, China.

Funding

Science and Technology Research Program of Sichuan Province 2023YFH0099
6 · The paper itself

Abstract

This study aimed to evaluate the biomechanical compatibility of a modular hemipelvic prosthesis by comparing stress distributions between an implanted pelvis and a healthy pelvis. Finite element analysis was used to simulate bilateral standing loads on both models, analyzing critical regions such as the sacroiliac joints, iliac crest, acetabulum, and prosthesis connection points. Six models with varied displacements of the hip joint rotational center were also introduced to assess the impact of deviations on stress distribution. The implanted pelvis had a stress distribution closely matching that of the intact pelvis, indicating that the prosthesis design maintained the biomechanical integrity of the pelvis. Stress patterns in displacement models with deviations of less than 10 mm were similar to the standard model, with only minor changes in stress magnitude. However, backward, upward, and inward deviations resulted in stress concentrations, particularly in the prosthesis connection points, increasing the likelihood of mechanical failure. The modular hemipelvic prosthesis demonstrated good biomechanical compatibility with minimal impact on pelvic stress distribution, even with moderate deviations in the hip joint's rotational center; outward, forward, and downward displacements are preferable to minimize stress concentration and prevent implant failure in cases where minor deviations in the rotational center are unavoidable during surgery.

Indexed as

biomechanicscenter of rotationhemipelvic prosthesisstress distributionthree-dimensional finite element

Identifiers

PMID39330251
PMCPMC11433228

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.