ArticleEntropy (Basel, Switzerland)2024
Improving Transmission Line Fault Diagnosis Based on EEMD and Power Spectral Entropy.
Article in Entropy (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- SE-Attention Augmented Hybrid CNN-BiLSTM Model for Leakage Current-Based Detection of Cracked and Broken High-Voltage Porcelain Insulators.Biomimetics (Basel, Switzerland) · 2026Article
- Improving the Protection of Step-Down Transformers by Utilizing Percentage Differential Protection and Scale-Dependent Intrinsic Entropy.Entropy (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The fault diagnosis on a transmission line based on the characteristics of the power spectral entropy is proposed in this article. The data preprocessing for the experimental measurement is also introduced using the EEMD. The EEMD is used to preprocess experimental measurements, which are nonlinear and non-stationary fault signals, to overcome the mode mixing. This study focuses on the fault location detection of transmission lines during faults. The proposed method is adopted for different fault types through simulation under the fault point by collecting current and voltage signals at a distance from the fault point. An analysis and comprehensive evaluation of three-phase measured current and voltage signals at distinct fault locations is conducted. The form and position of the fault are distinguished directly and effectively, thereby significantly improving the transmission line efficiency and accuracy of fault diagnosis.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.