Evidence map›Paper›PMID 39329656›Full record

ArticleBioengineering (Basel, Switzerland)2024

Computational Modeling Approach to Profile Hemodynamical Behavior in a Healthy Aorta.

Ahmed M Al-Jumaily, Mohammad Al-Rawi, Djelloul Belkacemi, Radu Andy Sascău, Cristian Stătescu, Florin-Emilian Țurcanu, Larisa Anghel

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ahmed M Al-JumailyInstitute of Biomedical Technologies, Auckland University of Technology, Auckland 1010, New Zealand.ORCID 0000-0002-9826-0374
Mohammad Al-RawiCenter for Engineering and Industrial Design, Waikato Institute of Technology, Hamilton 3240, New Zealand.ORCID 0000-0002-5794-6871
Djelloul BelkacemiUnité de Développement des Equipements Solaires, UDES, Centre de Développement des Energies Renouvelables, CDER, Tipaza 42004, Algeria.ORCID 0000-0003-0726-3439
Radu Andy SascăuInternal Medicine Department, Grigore T. Popa University of Medicine and Pharmacy, 700503 Iași, Romania.
Cristian StătescuInternal Medicine Department, Grigore T. Popa University of Medicine and Pharmacy, 700503 Iași, Romania.ORCID 0000-0001-6439-4561
Florin-Emilian ȚurcanuBuilding Services Department, Faculty of Civil Engineering and Building Services, Gheorghe Asachi Technical University, 700050 Iaşi, Romania.ORCID 0000-0002-9678-5708
Larisa AnghelInternal Medicine Department, Grigore T. Popa University of Medicine and Pharmacy, 700503 Iași, Romania.ORCID 0000-0002-7925-3806

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Cardiovascular diseases (CVD) remain the leading cause of mortality among older adults. Early detection is critical as the prognosis for advanced-stage CVD is often poor. Consequently, non-invasive diagnostic tools that can assess hemodynamic function, particularly of the aorta, are essential. Computational fluid dynamics (CFD) has emerged as a promising method for simulating cardiovascular dynamics efficiently and cost-effectively, using increasingly accessible computational resources. This study developed a CFD model to assess the aorta geometry using tetrahedral and polyhedral meshes. A healthy aorta was modeled with mesh sizes ranging from 0.2 to 1 mm. Key hemodynamic parameters, including blood pressure waveform, pressure difference, wall shear stress (WSS), and associated wall parameters like relative residence time (RRT), oscillatory shear index (OSI), and endothelial cell activation potential (ECAP) were evaluated. The performance of the CFD simulations, focusing on accuracy and processing time, was assessed to determine clinical viability. The CFD model demonstrated clinically acceptable results, achieving over 95% accuracy while reducing simulation time by up to 54%. The entire simulation process, from image construction to the post-processing of results, was completed in under 120 min. Both mesh types (tetrahedral and polyhedral) provided reliable outputs for hemodynamic analysis. This study provides a novel demonstration of the impact of mesh type in obtaining accurate hemodynamic data, quickly and efficiently, using CFD simulations for non-invasive aortic assessments. The method is particularly beneficial for routine check-ups, offering improved diagnostics for populations with limited healthcare access or higher cardiovascular disease risk.

Indexed as

computational fluid dynamicsendothelial cell activation potentialhealthy aortapolyhedral meshtetrahedral mesh

Identifiers

PMID39329656
PMCPMC11428636

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.