Evidence map›Paper›PMID 39329562›Full record

ArticleBiomimetics (Basel, Switzerland)2024

Bioinspired Design of 3D-Printed Cellular Metamaterial Prosthetic Liners for Enhanced Comfort and Stability.

Vasja Plesec, Gregor Harih

Abstract read
In one paragraph

Article in Biomimetics (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Vasja PlesecLaboratory for Integrated Product Development and CAD, Faculty of Mechanical Engineering, University of Maribor, 2000 Maribor, Slovenia.ORCID 0000-0001-8147-2250
Gregor HarihLaboratory for Integrated Product Development and CAD, Faculty of Mechanical Engineering, University of Maribor, 2000 Maribor, Slovenia.

Funding

LEARNED MODIFICATION OF VISCERAL FUNCTIONS IN ANIMALSZ01AG000063 · NIA · AGING · PI ENGEL, B T · 1985 to 1995
–
Slovenian Research Agency Research Core Funding No. P2-0063
6 · The paper itself

Abstract

Traditional prosthetic liners are often limited in customization due to constraints in manufacturing processes and materials. Typically made from non-compressible elastomers, these liners can cause discomfort through uneven contact pressures and inadequate adaptation to the complex shape of the residual limb. This study explores the development of bioinspired cellular metamaterial prosthetic liners, designed using additive manufacturing techniques to improve comfort by reducing contact pressure and redistributing deformation at the limb-prosthesis interface. The gyroid unit cell was selected due to its favorable isotropic properties, ease of manufacturing, and ability to distribute loads efficiently. Following the initial unit cell identification analysis, the results from the uniaxial compression test on the metamaterial cellular samples were used to develop a multilinear material model, approximating the response of the metamaterial structure. Finite Element Analysis (FEA) using a previously developed generic limb-liner-socket model was employed to simulate and compare the biomechanical behavior of these novel liners against conventional silicone liners, focusing on key parameters such as peak contact pressure and liner deformation during donning, heel strike, and the push-off phase of the gait cycle. The results showed that while silicone liners provide good overall contact pressure reduction, cellular liners offer superior customization and performance optimization. The soft cellular liner significantly reduced peak contact pressure during donning compared to silicone liners but exhibited higher deformation, making it more suitable for sedentary individuals. In contrast, medium and hard cellular liners outperformed silicone liners for active individuals by reducing both contact pressure and deformation during dynamic gait phases, thereby enhancing stability. Specifically, a medium-density liner (10% infill) balanced contact pressure reduction with low deformation, offering a balance of comfort and stability. The hard cellular liner, ideal for high-impact activities, provided superior shape retention and support with lower liner deformation and comparable contact pressures to silicone liners. The results show that customizable stiffness in cellular metamaterial liners enables personalized design to address individual needs, whether focusing on comfort, stability, or both. These findings suggest that 3D-printed metamaterial liners could be a promising alternative to traditional prosthetic materials, warranting further research and clinical validation.

Indexed as

3D printingadditive manufacturingbioinspired designcellular structurefinite element methodlower-limb prostheticmetamaterial model

Identifiers

PMID39329562
PMCPMC11430568

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.